BOSS/SECRETARY CALLING

PROGRAMMING
To set up the Secretary station with the D
START
CM13
Assign the Secretary station to the required sta-
tion number.
If the Boss station is a Single-Line Telephone
with MW lamp, provide the Message Waiting
service to the Boss station.
CM90
Assign the Boss line key as a Secondary
Extension line to the Secretary's D
Assign the MW SET/MW RESET keys to the
Secretary's D
If the Boss station is a D
Lamp to the Boss' D
CM20
Assign the access code for MW Set/MW Reset
to the secretary's D
CM08
Whether Message Waiting/Message Reminder
is reset (turning the MW Lamp off) irrespec-
tive of answering of calling station when the
called station calls to retrieve the message.
Specify the MW Lamp indication pattern for
term
D
.
A
term
:
DESCRIPTION
term
term
, if needed.
term
, assign a MW
term
.
term
, if required.
Y=12
(1)
X-XXXXXXXX: My Line No. of Secre-
(2)
0: Secretary station
Y=03
(1)
X-XXXXXXXX: Boss Station No.
(2)
0: To provide
Y=00
.
(1)
My Line No. of Secretary +
(2)
X-XXXXXXXX: Boss Station No. /Boss
Y=00
(1)
My Line No. of Secretary +
(2)
F0040: MW Set
F0041: MW Reset
Y=00
(1)
My Line No. of Boss +
(2)
F1005: MW Lamp
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A040: MW Set
A041: MW Reset
(1)
234
(2)
0 : Available
1 : Not available (Reset by answering of
calling station)
(1)
294
(2)
0 : Flashing (60 IPM)
1 : Steady lighting
– 130 –
BOSS/SECRETARY CALLING
DATA
tary
,
+ Key No.
My Line No.
,
+ Key No.
,
+ Key No.