Philips Sopho 2000 IPS User Manual page 362

Hide thumbs Also See for Sopho 2000 IPS:
Table of Contents

Advertisement

C
CM35
Provide the distinctive ringing patterns to a
term
D
in behind PBX.
CM30
Specify the terminating system for incoming
C.O. calls.
Provide the Trunk-Direct Appearances on
term
D
.
CM41
Assign the ringing detect timer for incoming
trunk calls.
Assign the main PBX (Centrex) ringing
distinction timer.
Assign the immediate ringing guard timer
from the main PBX (Centrex).
D
DESCRIPTION
NOTE 1
on next page
NOTE 1, NOTE 2
on next page
Y=87
(1)
00-63: Trunk Route No.
(2)
0 : To provide
1 : Not provided
Y=02 in Day Mode
Y=03 in Night Mode
Y=40 in Mode A
Y=41 in Mode B
(1)
000-255: Trunk No.
(2)
02: Trunk-Direct Appearances
03: Trunk-Direct Appearances + TAS
Y=18
(1)
000-255: Trunk No.
(2)
0 : To provide
1 : Not provided
Y=2
(1)
00
(2)
06-10: 192-320 ms.
If no data is set, the default setting is 256-288
ms.
Y=2
(1)
40
(2)
01-15: 128-1920 ms.
If no data is set, the default setting is 1280-1408
ms.
Y=2
(1)
41
(2)
00-90: 0-12672 ms.
If no data is set, the default setting is 384-512
ms.
– 344 –
DISTINCTIVE RINGING
DATA
(32 ms. increments)
(128 ms. increments)
(128 ms. increments)
NWA-008845-001 Rev.5.0
32ch1006.fm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents