A
CME9
Assign the setting/changing of the password to
be allowed.
Assign a password to each Password Level.
Provide the system with Password Feature. Af-
ter setting this data, access to system program-
ming is only available with password entry.
END
NOTE:
If the Password Service is provided, enter the predetermined password (assigned by
CME9>0-7) by CM03 before programming from the MAT.
+ 03 +
ST
– "OK" will be displayed, if accepted.
– "DATA ERROR" will be displayed if the password is incorrect.
HARDWARE REQUIRED
Refer to "MATWorX Installation Guide".
DESCRIPTION
+ Password Level No. (0-7) +
DE
MAINTENANCE ADMINISTRATION TERMINAL (MAT)
(1)
8
(2)
0 : Allowed
1 : Restricted
(1)
0-7: Password Level 0-7
(2)
X-X...X: Maximum 8 digits Password
CCC
A password for Password Level 7 should be as-
signed in advance because of providing the
password service by Function No. 9 of CME9.
The following passwords are not available.
"CCCCCCCC"
"FFFFFFFF"
The setting/changing of the password is avail-
able only when the second data of CME9>8 is
set to "0 (Allowed)".
If CME9>8 is set to "1 (Restricted)", "DATA
ERROR" is displayed when you set/change the
password.
(1)
9
(2)
0: Provided
+ Password +
DE
– 443 –
DATA
: Password clear
EXE
NWA-008845-001 Rev.5.0
DECEMBER/02/2005