PERIODIC TIME INDICATION TONE

PROGRAMMING
START
CM08
Provide the system with this feature.
And specify availability of this service on Tie
Line call.
CM12
Assign Service Restriction Class B for this
feature to required stations.
CM15
Allow Periodic Time Indication Tone in
Service Restriction Class B assigned by CM12
Y=02.
CM13
Assign required stations as Ordinary Station.
If assigned to 0 (Analog Data Station), this
feature will not be applied to the station.
CM41
Specify the timing interval for Periodic Time
Indication Tone.
END
DESCRIPTION
PERIODIC TIME INDICATION TONE
(1)
135: On outgoing C.O. line call
(2)
0: To provide
(1)
136: On outgoing Tie line call
(2)
0 : To provide
1 : Not provided
Y=02
(1)
X-XXXXXXXX: Station No.
(2)
XX ZZ
ZZ: 00-15 : Service Restriction Class B
Y=61
(1)
00-15: Service Restriction Class B as-
(2)
1 : Allow
Y=07
(1)
X-XXXXXXXX: Station No.
(2)
1 : Ordinary Station
Y=0
(1)
09
(2)
01-17: 32-548 seconds
If no data is set, the default setting is 192-196
seconds.
– 559 –
DATA
signed by CM12 Y=02
(32 second increments)
NWA-008845-001 Rev.5.0