D
CM41
Specify the various timing for the DTI trunk, if
required.
E
DESCRIPTION
Y=3
(1)
04: Ringing Signal Detect Timing
(2)
01-15: 32-480 ms. (32 ms. increments)
If no data is set, the default setting is 192 ms.
Y=3
(1)
05: Release Signal Detect Timing
(2)
01-15: 64-960 ms. (64 ms. increments)
If no data is set, the default setting is 512 ms.
Y=3
(1)
06: Answer Signal Detect Timing
(2)
01-15: 64-960 ms. (64 ms. increments)
If no data is set, the default setting is 576 ms.
Y=3
(1)
07: Ringing Signal Detect Time out
(2)
01-15: 512-7680 ms. (512 ms. increments)
If no data is set, the default setting is 7,168 ms.
Y=3
(1)
08: Guard Timing of DTI release
(2)
01-15: 128-1920 ms. (128 ms. increments)
If no data is set, the default setting is 512 ms.
Y=3
(1)
09: Hooking Signal sending timing
(2)
01-15: 64-960 ms. (64 ms. increments)
If no data is set, the default setting is 640 ms.