CODE CALLING EQUIPMENT ACCESS

PROGRAMMING
START
CM10
Assign the interface trunk (COT card and DK
card) to the required LEN.
NOTE 1:
CM14
Assign the interface trunk (COT card and DK
card) to the required LEN.
[Series 3200 R6.2 software required]
NOTE 1:
CM08
Specify ON/OFF condition for external relay/
external key on MP built-in DK00 card.
A
DESCRIPTION
The DK card number must be as-
signed to the first LEN (Level 0) and
the third LEN (Level 2) of each LT
Slot.
The DK card number must be as-
signed to the first LEN (Level 0) and
the third LEN (Level 2) of each LT
Slot.
MISCELLANEOUS TRUNK ACCESS
CODE CALLING EQUIPMENT ACCESS
(1)
000-763: LEN
(2)
D000-D255: COT card
E800-E831 : DK card
For PIM0/1: E800-E807
For PIM2/3: E808-E815
For PIM4/5: E816-E823
For PIM6/7: E824-E831
NOTE 2:
(1)
XX ZZZ: LEN
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
(2)
D000-D255: COT card
E800-E831 : DK card
For FP No. 00: E800-E807
For FP No. 01: E808-E815
For FP No. 02: E816-E823
For FP No. 03: E824-E831
NOTE 2:
(1)
700
(2)
0 : ON (Ground Start)
OFF (Ground Off [Open])
1 : ON (Ground Off [Open])
OFF (Ground Start)
– 481 –
DATA
Circuit No. 3 of E831 is used for
built-in External Equipment In-
terface of MP card by setting
CM44.
Circuit No. 3 of E831 is used for
built-in External Equipment In-
terface of MP card by setting
CM44.
NWA-008845-001 Rev.5.0
JULY/01/2006
32ch1008.fm