Fault 54: Sv2 Out - Toro Reelmaster 5010-H Diagnostic Manual

Hide thumbs Also See for Reelmaster 5010-H:
Table of Contents

Advertisement

Fault 54: SV2 Out

InfoCenter Display:
Fault Description
The output current is too high from the TEC-5002 to the SV2 hydraulic lift/lower solenoid.
Circuit Description
The TEC controller uses inputs from various machine switches to determine when lift manifold solenoid valves
(SV1, SV2, SV3, and SVRV) are to be energized.
Conditions for Setting the Fault
There must be an electrical failure in the SV2 circuit to trigger this fault. It could be damaged wiring, a shorted
coil, or a malfunctioning TEC-5002 controller.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
Step 2: Test the wiring and coil resistance of SV2.
This Step measures the resistance of the wiring and the coil for SV2.
Use a multimeter to test the resistance between the following pair of locations:
Location
Harness
1
Seat
2
Pass
The measurement was good. Go to Step 5.
Fail
The measurement was bad. Go to Step 3.
_____FAULT
Returning the Machine to Service (page 22)
Connector
Pin
P75
5
Chassis ground
#54_____
SV2
OUT
Clearing Faults from the InfoCenter (page
Wire
Expected
Color
Reading
Violet
Approx.
8 ohms
191
21).
and follow the steps listed.
Connector Graphic

Advertisement

Table of Contents
loading

This manual is also suitable for:

03674

Table of Contents