3.
Rotate the ignition key to the O
4.
Measure the voltage between pins 1 and 2 of connector P41. The reading should be 48 Vdc.
5.
Measure the voltage between P40 pin 1 and P41 pin 2. The reading should be 48 Vdc.
6.
Rotate the ignition key to the O
Pass
The voltage readings were good. Go to Step 7.
Fail
The voltage readings were not good. Go to Step 6.
Step 6: Test the power and ground wiring in main harness connectors
P40 and P41.
These are diagnostic steps to help isolate problems identified in Step 5. Use a multimeter to test the resistance
between the following pairs of locations:
Location
Harness
1
Main
2
Main
1
Main
2
Main
1
Main
2
Main
Pass
The resistance tests passed, but the voltage readings in Step 5 are still bad.
Note:
Do not go to Step 7 until after the voltage readings in Step 5 are good.
Fail
One or more of the power and ground wiring tests failed. Repair or replace the worn or damaged
parts. Go to
position.
N
position.
FF
Pin
Connector
P41
1
P37
3
P41
2
P37
4
P40
1
P41
2
Returning the Machine to Service (page 22)
Wire
Expected
Color
Reading
Red
Less than
2 ohms
Red
Black
(48V
Ground)
Less than
2 ohms
Black
(48V
Ground)
White
24 k to 26k
ohms
Black
(48V
Ground)
and follow the steps listed.
135