Fault 21: Id Module Fault - Toro Reelmaster 5010-H Diagnostic Manual

Hide thumbs Also See for Reelmaster 5010-H:
Table of Contents

Advertisement

Fault 21: ID Module Fault

InfoCenter Display:
Fault Description
Each cutting reel motor has its own unique module ID. This fault is reported when either:
an ID module is not functioning at all, or
more than 1 cutting reel motor is claiming the same node ID
Circuit Description
Each cutting reel motor has an electronic signature code so it can be identified. These codes are all maintained
within the location ID module. If an ID code is missing, or if more than 1 cutting reel motor reports having the
same code to the TEC-5002, fault 21 is reported.
Conditions for Setting the Fault
The TEC-5002 has recognized an error in the way 1 or more of the module IDs are functioning.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
Step 2: Test the location ID module.
1.
Go to
Preparing for Troubleshooting and/or Testing (page 22)
2.
Raise and support the operator's seat and the hood.
3.
Separate system components from the 48 Vdc battery pack by unplugging the 48 Vdc battery disconnect.
Refer to
Connecting and Disconnecting the 48 Vdc Battery System (page
_____FAULT
#21_____
ID Module
Clearing Faults from the InfoCenter (page
Returning the Machine to Service (page 22)
76
and follow the steps listed.
and follow the steps listed.
19).
21).