Toro Reelmaster 5010-H Diagnostic Manual page 358

Hide thumbs Also See for Reelmaster 5010-H:
Table of Contents

Advertisement

3.
Locate and remove fuse F2-5 (35 amp) for testing.
4.
Measure the resistance of the fuse. The reading should be 1 ohm or less.
Pass
The fuse tested good. Install fuse F2-5. Go to Step 3.
Fail
The fuse failed the test. Replace the fuse. Go to
follow the steps listed.
Step 3: Inspect the wiring for cutting reel motor 5.
1.
Refer to
Figure 154
1. Cutting unit 1, which includes cutting reel motor 1
2. Cutting unit 2, which includes cutting reel motor 2
3. Cutting unit 3, which includes cutting reel motor 3
2.
Follow the cutting reel motor cable from cutting reel motor 5 to the connector plate mounted on the
traction unit.
Note:
The 2 cutting reel motor cable connectors are secured with clips to the connector plate. The 2
main harness connectors are not secured to the connector plate.
3.
Disconnect main harness connectors P44 and P45 from the cutting reel motor cable connectors mounted
on the traction unit.
4.
Inspect the 2 cutting reel motor cable connectors and the 2 main harness connectors for the following:
damage
corrosion
debris
proper alignment and seating of the pins inside the connectors
5.
Inspect the 2 cutting reel motor cable connectors for proper wire color per pin, as shown in the following 2
tables.
to locate cutting reel motor 5.
Cutting Reel Motor, 4-Pin Connector
Returning the Machine to Service (page 22)
Figure 154
4. Cutting unit 4, which includes cutting reel motor 4
5. Cutting unit 5, which includes cutting reel motor 5
358
and
g032972