Toro Reelmaster 5010-H Diagnostic Manual page 102

Hide thumbs Also See for Reelmaster 5010-H:
Table of Contents

Advertisement

1. Battery covers
2. 12 Vdc AGM batteries (4)
B.
Measure the voltage across each of the 4 individual batteries. The individual battery readings should
be 11.5 to 13.5 Vdc.
2.
Inspect the following cables for damage, corrosion, and proper installation
The cables between the 4 individual batteries
The cables between the battery pack and the machine.
Pass
The 48 Vdc battery system checks were good. Install the battery covers and cutting unit 1. Go
to Step 4.
Fail
One or more of the 48 Vdc battery system tests failed. Repair or replace the worn or damaged parts.
Go to
Returning the Machine to Service (page 22)
Step 4: Replace the main 48 Vdc contactor.
1.
Refer to Chapter 5 of the 5010-H Service Manual and replace the main contactor.
2.
Go to
Returning the Machine to Service (page 22)
Figure 71
3. Battery cables
and follow the steps listed.
and follow the steps listed.
102
(Figure
71).
g036201

Advertisement

Table of Contents
loading

This manual is also suitable for:

03674