3.
Turn the ignition key to the O
Location
Harness
1
Main
2
Main
Pass
The isolation module power test was good. Go to Step 7.
Fail
The isolation module power test failed. Repair or replace the damaged wiring. Go to
Machine to Service (page 22)
Step 7: Test the CAN bus wiring to the isolation module.
1. CAN bus isolation module
Use a multimeter to test the resistance between the following pairs of locations:
Location
Harness
1
Main
2
Main
1
Main
2
1
Main
2
position.
FF
Connector
Pin
P42
A
P42
B
(Ground)
and follow the steps listed.
Connector
Pin
P42
C
P42
D
P42
C
Chassis ground
P42
D
Chassis ground
Wire
Expected
Color
Reading
Pink
12 Vdc
Black
Figure 68
Wire
Expected
Color
Reading
Black/
White
54 to 66
ohms
Red/
White
Black/
Open
White
(infinite)
Red/
Open
White
(infinite)
98
Connector Graphic
Returning the
Connector Graphic
g033103

Advertisement

Table of Contents
loading

This manual is also suitable for:

03674

Table of Contents