1. 48V battery disconnect
2. 250A/58V fuse
3. Contactor coil posts
Pass
The main contactor tested good. Go to Step 3.
Fail
The main contactor did not test good. Replace the main contactor. Refer to Chapter 5 of the 5010-H
Service Manual. Go to
Step 3: Test the control wiring for the contactor coil.
1.
Use a multimeter to test the resistance between the following pairs of locations:
Location
Harness
1
Main
2
Main
Figure 123
Returning the Machine to Service (page 22)
Connector
Pin
J25
1
P37
2
4. Main 48 Vdc contactor
5. Main contact posts
Wire
Expected
Color
Reading
Brown
Less than
2 ohms
Brown
212
and follow the steps listed.
Connector Graphic
g033200