Toro Reelmaster 5010-H Diagnostic Manual page 110

Hide thumbs Also See for Reelmaster 5010-H:
Table of Contents

Advertisement

1. Battery covers
2. 12 Vdc AGM batteries (4)
B.
Each individual battery should read 11.5 to 13.5 Vdc.
3.
Inspect the following cables for damage, corrosion, and proper installation
The cables between the 4 individual batteries
The cables between the battery pack and the machine.
Pass
The 48 Vdc battery system checks were good. Go to Step 3.
Fail
One or more of the 48 Vdc battery system tests failed. Repair or replace the worn or damaged parts.
Go to
Returning the Machine to Service (page 22)
Step 3: With the engine running, check the 48 Vdc battery system.
1.
Use a multimeter to measure the voltage across the 48 Vdc battery pack
2.
The acceptable voltage range is 46 to 67.5 Vdc.
Pass
The 48 Vdc battery system check was good. Go to
and follow the steps listed.
Fail
The 48 Vdc battery system check was not good. Go to Step 4.
Figure 77
3. Battery cables
and follow the steps listed.
Returning the Machine to Service (page 22)
110
(Figure
77).
(Figure
76).
g036201

Advertisement

Table of Contents
loading

This manual is also suitable for:

03674

Table of Contents