1. Hydraulic lift manifold
2. Operator's seat
4.
Locate the SVRV solenoid on the lift manifold. See
1. SV1 solenoid
2. SV2 solenoid
3. SV3 solenoid
5.
Unplug main harness connector P18 and use a multimeter to measure the resistance of the SVRV coil.
It should be approximately 7.1 ohms.
Figure 118
3. 48V disconnect
Figure
119.
Figure 119
4. SVRV (SV4) solenoid
5. Lift manifold