1. 48V disconnect
2. Operator's seat
3.
Use a multimeter and measure the 48 Vdc battery pack voltage across the main contactor
The acceptable voltage range is 46 to 54 Vdc.
Note:
If you measure less than 46 Vdc, measure the voltage across each of the 4 individual batteries.
Each individual battery is within the service limit if you measure 11.5 to 13.5 Vdc.
Figure 64
3. Main contactor
Figure 65
95
g035727
(Figure
65).
g036085