Step 4: Test the power and ground wiring in main harness connectors
P46 and P47.
These are diagnostic steps to help isolate problems identified in Step 3. Use a multimeter to test the resistance
between the following pairs of locations:
Location
Harness
1
Main
2
Main
1
Main
2
Main
1
Main
2
Main
Pass
The resistance tests passed, but the voltage readings in Step 3 are still bad.
Note:
Do not go to Step 5 until after the voltage readings in Step 3 are good.
Fail
One or more of the power and ground wiring tests failed. Repair or replace the worn or damaged
parts. Go to
Returning the Machine to Service (page 22)
Step 5: Swap cutting reel motors between cutting units.
All of the cutting reel motors are identical.
1.
Go to
Preparing for Troubleshooting and/or Testing (page 22)
2.
Unplug the 48 Vdc battery disconnect to prevent unexpected cutting unit operation. Refer to
and Disconnecting the 48 Vdc Battery System (page
3.
Swap cutting reel motor 1 with a cutting reel motor from a different cutting unit. You can obtain more
information on replacing the cutting reel motor in Chapter 5 of the 5010-H Service Manual.
Connector
Pin
P47
1
P37
3
P47
2
Ground)
P37
4
Ground)
P46
1
P47
2
Ground)
Wire
Expected
Color
Reading
Red
Less than
2 ohms
Red
Black
(48V
Less than
2 ohms
Black
(48V
White
24k to 26k
ohms
Black
(48V
and follow the steps listed.
and follow the steps listed.
19).