* c. Separation roller
Apply an even coat of grease (Alvania No.2) to all round the inside of the spring.
When replacing the separation roller, apply adequate amount of white grease (Molykote HP-300)
on the places of the holder shown in the figure (4 places).
Notes:
Make sure that the grease does not adhere to the roller surface. Wipe it off with alcohol if
adhered.
Apply grease on the inner surface
Fig. 7-12
* e. Registration roller (Pusher)
Apply 2 rice-sized grains of white grease (Molykote EM-30L) to the 2 contact points of the
registration roller (rubber) and the pusher.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
PREVENTIVE MAINTENANCE (PM)
Apply white grease
Registration roller
Grease
Pusher
Fig. 7-14