[D] Reproduction ratio adjustment of the secondary scanning direction
<Procedure>
While pressing [0] and [5] simultaneously, turn the power ON.  (Adjustment Mode)
(1)
(2)
Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3)
Press [FAX] -> [START] to make a copy at the mode of A3 (LD), 100% and the lower drawer
(Refer to *).
(4)
Measure the distance C from 200 mm to 400 mm of the copied image of the ruler.
(5)
Check if the distance C is within the range of 200±0.5 mm.
(6)
If not, use the following procedure to change values and repeat steps (3) to (5) above.
(Adjustment Mode)  (Key in the code [3032])  [START]
 (Key in a value (acceptable values: 63 to 193))
 Press the [OK] or the [INTERRUPT] button (stored in memory).
 ("100% A" is displayed.)
* The smaller the adjustment value is, the lower the reproduction ratio becomes.
e-STUDIO206L/256/306/356/456/506: approx. 0.05 mm/step
e-STUDIO207L/257/307/357/457/507: approx. 0.45 mm/step
50
100
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Copied image of the ruler
150
200
250
Feeding direction
Fig.6-15
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
6 - 17
300
350
400
C
SETTING / ADJUSTMENT