[E860] RADF jam access cover open
Classification
RADF jam
Check item
RADF jam access cover
RADF jam access cover switch •
RADF board
Parts to be replaced
RADF jam access cover switch
RADF board
[E870] RADF open jam
Classification
RADF jam
Check item
RADF
RADF opening/closing sensor
RADF board
Parts to be replaced
RADF opening/closing sensor
RADF board
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
Error content

RADF jam access cover open

Measures
Close the RADF jam access cover if it is opened. Remove if there is
any original before closing it.
Sensor check
(Perform the input check: 03-[FAX] ON[7]/[C])
Connector check (CN8)
Harness check
Board check
Connector check (CN8)
Harness check
Remark

RADF open jam

Close the RADF if it is opened. Remove if there is any original
before closing it.
Sensor check
(Perform the input check: 03-[FAX] ON[7]/[D])
Connector check (CN75)
Harness check
Board check
Connector check (CN75)
Harness check
Is the RADF opening/closing sensor adjusted within the specified
range?