Toshiba e-STUDIO206L Service Manual page 430

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

[ 2 ] Operation
Notes:
When adjusting output of high-voltage transformer, make sure to use the high-voltage
transformer jig.
Connect the digital testers as described in "[1] Preparation", and follow the procedure on the next
page to adjust the output from the main charger, developer bias charger, transfer charger and
separation charger.
<Keys to press>
[0][5]
[POWER]
1
[Digital keys]
: Enter the code.
[START]
[UP] or [DOWN]: Adjust the value "YYY" to satisfy the following table.
Developer bias
Main charger bias
Transfer bias
Separation bias
Transfer cleaning
bias(positive)
Transfer cleaning
bias(negative)
[OK]
: Adjusted value "YYY" is stored in memory.
or
[INTERRUPT]
Return to 1 to enter
the other adjustment
code.
[POWER] : OFF/ON
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
SETTING / ADJUSTMENT
<Display>
100%
TEST MODE
100%
TEST MODE
YYY
Code
Item
206L/256/306
2020
-377 5V
2040
-502 5V
2052
1600 55mV
2078
2083
1000 55mV
2084
-322 55mV
100%
TEST MODE
Fig.6-30
6 - 50
A
XXX
Current set value
Adjustment value
e-STUOIO
207L/257/307
-427 5V
-547 5V
2300 55mV
55mV
1800 55mV
A
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
A3
A3
Code No.
356/456/506
357/457/507
-377 5V
-427 5V
-516 5V
-558 5V
-402 55mV
-322 55mV
A3

Hide quick links:

Advertisement

Table of Contents