[C1A0] Lcf End Fence Motor Is Abnormal - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

[C1A0] LCF end fence motor is abnormal

Classification
Paper feeding system related service
call
Proce
Check item
dure
1
Is the LCF end fence
motor working? (Perform
the output check in the
test mode: 03-207)
2
Are the LCF end fence
home/stop position
sensors working?
(Perform the input check
in the test mode: 03-
[FAX]OFF/[5]/[D], /[5]/[C])
3
LGC board
Parts to be replaced
LCF board
LGC board
LCF end fence motor
End fence home/stop position
sensors
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
LCF end fence motor is abnormal
Result
Yes
No
1. Check if the connector of the LCF end fence
motor is disconnected.
2. Check if any of the connectors CN1 and
CN5 on the LCF board is disconnected.
3. Check if the connector CN318 on the LGC
board is disconnected.
4. Check if the connector pins are
disconnected and the harnesses are open
circuited.
5. Check if the conductor patterns on the LCF
board and LGC board are short circuited or
open circuited.
6. Replace the LCF board.
7. Replace the LGC board.
Yes
No
1. Check if the connectors of the sensors are
disconnected.
2. Check if either of the connectors CN1 or
CN4 on the LCF board is disconnected.
3. heck if the connector CN318 on the LGC
board is disconnected.
4. Check if the slit reaches the sensors.
5. Check if the connector pins are
disconnected and the harnesses are open
circuited.
6. Check if the conductor patterns on the LCF
board and LGC board are short circuited or
open circuited.
7. Replace the LCF board.
8. Replace the LGC board.
1. Check if the conductor pattern on the LGC
board is short circuited or open circuited.
2. Replace the LGC board.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
8 - 126
Error content
Measure
Remark
Next
Step
2
3

Hide quick links:

Advertisement