[E] Restore SRAM
If there is SRAM backup data, perform the following steps.
(1)
Turn the power ON while pressing [6] and the [CLEAR] button simultaneously.
(2)
When "SRAM Clear Mode" appears on the LCD, key in [0] to select "0. Set Serial Number" and
then press the [START] button.
(3)
Key in the serial number on the label attached to the rear cover of the equipment, and then press
the [OK] button.
(4)
"Serial Number Setting completed" is displayed.
(5)
Turn the power OFF.
(6)
Install the USB media in the equipment, and then turn the power ON while pressing [5] and [9]
simultaneously.
(7)
Key in [2] to select "2. Restore SRAM Data from USB" and then press the [START] button.
(8)
Enter the password set for the backup data.
(9)
Enter the serial number of the backup file.
(10) Turn the power OFF after the restoring of SRAM is completed.
Remarks:
When the restoration is completed successfully, do not perform "[F] Clear SRAM update error
flags" or later procedures. End this procedure here and finish replacing the SRAM board (for
SYS board).
Notes:
When the back-up file is restored, do not perform HDD partition creation (Format HDD) before
the normal start-up.
(11) e-STUDIO206L/256/306/356/456/506: If the FAX unit (GD-1250) is installed, connect the
connector (CN134).
(12) e-STUDIO207L/257/307/357/457/507: If the FAX unit (GD-1350) is installed, connect the USB
connector (CN117).
[F] Clear SRAM update Error flags
(1)
Turn the power ON while pressing [3] and the [CLEAR] button simultaneously.
(2)
Enter the password, and then press the [OK] button.
(If the password is not set for Service, press the [OK] button without entering anything.)
(3)
After "Firmware Assist Mode" is displayed on the LCD, check that "1: Clear Error Flag in Software
Installation." is marked and press the [START] button.
If not, key in [1] and then press the [START] button.
(4)
When "Operation Complete" is displayed on the LCD, clearing the flag is completed.
(5)
Turn the power OFF.
[G] Backup ADI key
Perform the following procedures if the ADI-HDD has been installed.
(1)
Turn the power ON while pressing [3] and the [CLEAR] button simultaneously.
(2)
Enter the password, and then press the [OK] button.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
9 - 33
REPLACEMENT OF HDD/PC BOARDS