Toshiba e-STUDIO206L Service Manual page 173

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

4 Handle the unit with care. Do not touch
the adjusted area and lens. (Hold the unit
as the right figure.)
[B] 3-line CCD
(1)
Take off the lens cover.
 P. 4-26 "4.5.2 Lens cover"
(2)
Remove 1 screw and take off the APS
sensor.
(3)
Disconnect 1 connector and remove 4
screws. Take off the lens unit.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Fig. 4-96
Fig. 4-97
Fig. 4-98
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
4 - 33