e-STUDIO206L/256/306/356/456/506
e-STUDIO207L/257/307/357/457/507
Notes:
Fine adjustment can be made in the "Reproduction ratio of primary scanning direction (printer)".
on the copied ruler and actual ruler match.
(4)
Tighten 4 screws fixing the lens unit.
(5)
Attach the lens cover and original glass. Make a copy to confirm the reproduction ratio.
(6)
Repeat the procedure 1 to 5 until the marks on the copied ruler and actual ruler match.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Lens unit
Fig.6-45
Lens unit
Fig.6-46
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
6 - 61
SETTING / ADJUSTMENT
6