[C290] Scanner fuse blowout (e-STUDIO206L/256/306/356/456/506)
Classification
Scanning system related
service call
Check item
Is 24V supplied to the SLG
board?
Parts to be replaced
SLG board
Fuse
Supply harness
LVPS
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
The scanning system does not operate due to a blowout of the fuse
in the scanning system.
Result
Yes
Check the following because the signal for checking
24V on the SLG board is abnormal.
1. Check if 3V is input in 35 Pin of the scanner CPU
(IC10).
2. Check if the mounted parts on the SLG board are
damaged or abnormal.
3. Check if 24V on the SLG board is short circuited.
4. Check if 24V is supplied to the SLG board.
No
1. Check if the supply harness is connected properly to
the connector.
2. Check if 24V and SG on the SLG board are short
circuited.
3. Check if the power supply is short circuited by
pulling out the supply harness on the SLG board.
4. Check if the fuse on the LVPS is open circuited.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
8 - 136
Error content
Measure
Remark