When the update is completed properly, the LED on the download jig blinks.
The LED starts blinking approx. 15 sec. after the update starts. It is assumed that the update has
failed if it does not start blinking even though 1 min. has passed. In this case, shut down the
equipment and check the following items. Then clear the problems and restart updating from the
beginning.
-
Is the download jig connected properly?
-
Is the updating data written to the download jig properly?
-
Do the download jig and the equipment operate properly?
(8)
Press the [ON/OFF] button on the control panel to shut down the equipment and turn the power
OFF using the main power switch.
Notes:
"Update Failed." is displayed at the bottom of the LCD screen when the updating is not
completed properly. "Failed" appears next to the failed item on the status display. In this case,
shut down the equipment and check the following items. Then clear the problems and restart
updating from the beginning.
(9)
Remove the download jig.
(10) Install the cover plate and then close the front cover.
[B] Confirmation of the updated data
After the updating is completed, check each data version in the Setting Mode (08) to confirm that the
data were overwritten properly.
 P. 11-81 "11.7 Confirmation of the updated data"
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
11 - 43
FIRMWARE UPDATING