[Cc51] Sideways Adjustment Motor (M2) Abnormality; [Cc51] Punch Unit Sliding Motor (M12) Abnormality - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

[CC51] Sideways adjustment motor (M2) abnormality

MJ-1101/1106 (when MJ-6103 is installed), MJ-1107/1108 (when MJ-6104 is installed)
* You receive a [CC51] error when the [ED11] error occurs three times in succession or occurs during
the initialization.
Classification
Finisher related service call
Check Item
Transport path
Sideways adjustment motor (M2)
Sideways deviation home position
sensor (S3)
Replacement part
Sideways adjustment motor (M2)
Hole punch control PC board (HP)
Sideways deviation home position
sensor (S3)

[CC51] Punch unit sliding motor (M12) abnormality

MJ-1032
Error
Punch unit sliding motor (M12)
Punch sliding unit home position
sensor (S23)
Probable cause
Punch unit sliding motor (M12)
abnormality
Punch sliding unit home position
sensor (S23) abnormality
Faulty cables and connectors
Hole punch control PC board (HP)
abnormality
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
Sideways adjustment motor (M2) abnormality: Sideways
adjustment motor is not rotating or puncher is not shifting
normally.
If there is any paper remaining on the transport path, remove
the paper.
If there is mechanical problem when the sideways
adjustment motor (M2) is rotated, fix the mechanism.
Check the connectors and harnesses between the hole
punch control PC board (HP) and sideways adjustment
motor (M2).
Sensor check
Harness check
Timing of detection
The punch sliding unit is not slid after sliding request is sent.
The punch sliding unit home position sensor (S23) does not detect that
the unit is at its home position after the specified time when the unit is
returned to the home position, or this sensor does not detect that the
unit is out of its home position after the specified time when the unit is
released.
The punch sliding unit home position sensor (S23) does not detect that
the unit is at its home position after the specified time when the unit is
moved, or this sensor does not detect that the unit is at its home
position when the unit is released.
Checking and measures
Check if the electrical continuity of the coil is normal. If electricity is not
conducted, replace the motor.
Measure the voltage on TP26 on the hole punch control PC board
(HP). Then check that the measured voltage is 1V or lower when not
shielded and within the range of 5V5% when shielded. If the voltage
does not fall within the range mentioned, replace the sensor.
Check if the electrical continuity between the connector terminals is
normal. If electricity is not conducted, replace the connector. (Hole
punch control PC board (HP): CN3, CN5, CN6)
If the error still occurs after replacing the motor, sensor and
connectors, exchange the hole punch control PC board (HP).
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
8 - 180
Contents
Measure
Measure

Hide quick links:

Advertisement

Table of Contents