Parts to be replaced
Transfer roller
[E510] ADU stack jam (paper not reaching the ADU entrance sensor
Classification
Paper transport jam (ADU section) Jam not reaching the ADU entrance sensor
Proce
Check item
dure
1
Open the ADU. Is there
any paper in front of the
ADU entrance sensor?
2
Is the ADU entrance
sensor working? (Perform
the input check in the test
mode: 03-[FAX]OFF/[1]/
[D])
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
Result
Yes
Remove the paper.
No
Yes
No
•
Check if the connector of the ADU entrance
sensor is disconnected.
•
Check if the connector CN311 on the LGC
board is disconnected.
•
Check if the connector pins are
disconnected and the harnesses are open
circuited.
•
Check if the conductor patterns on the MOT
board and LGC board are short circuited or
open circuited. (e-STUDIO206L/256/306 /
207L/257/307)
•
Check if the conductor patterns on the
MOT2 board and LGC board are short
circuited or open circuited.
(e-STUDIO356/456/506 / 357/457/507)
•
Replace the ADU entrance sensor.
•
Replace the LGC board.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
8 - 50
Remark
Error content
Measure
Next
Step
2
3