Connect the download jig [1] with the jig connector (CN28) on the Finisher control board.
(5)
Turn ON the power while pressing [0] and [8] simultaneously.
Updating starts and the LED on the download jig lights.
(6)
When the update completes normally, the LED on the download jig starts blinking.
The LED on the download jig starts blinking in approx. 12 seconds after the update started.
It is assumed that the update is failed if the LED does not start blinking even after 20 seconds
have elapsed.
In this case, turn the power OFF and check the following items.
Then, clear the problem and restart updating from the beginning.
Is the download jig connected properly?
Is the ROM attached to the download jig properly?
Has the update data been written correctly to the ROM on the download jig?
Is the download jig or the equipment damaged?
(7)
Turn the power OFF and remove the download jig.
(8)
Install the board access cover.
[B] Confirmation of the updated data
After the updating is completed, check each data version in Setting Mode (08) to confirm that the data
were overwritten properly.
 P. 11-81 "11.7 Confirmation of the updated data"
11.5.7

Hole punch unit firmware (MJ-6008)

The update procedure of the hole punch control PC board (HP) is the same as that of the finisher
control PC board (FIN). The data in the update ROM are automatically judged and stored whether they
are for the finisher control PC board (FIN) or hole punch control board (HP).
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
FIRMWARE UPDATING
[ 1 ]
Fig.11-47
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved