Warning
Message
Type
MCT Timeout # Set
MCT Timeout # Clear
ECT Timeout #
Set
ECT Timeout #
Set
ECT Timeout #
Clear
Memory Usage
Set
Host
Memory Usage
Clear
Host
OL-31980 -01
Message
Cause/Remedy
MCT # is lost
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
MCT fault
–
cleared
ECT # timed out
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
ECT # is lost
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
ECT fault cleared –
Excessive
Cause: Possible software
(stack/partition)
issue.
memory usage
Remedy: Clear
warnings, reset the unit,
and notify Cisco
customer support if the
problem persists.
Normal
–
(stack/partition)
memory usage
Description
No longer receiving
Inband Control Table.
–
Event Control Table
was never received.
No longer receiving
Event Control Table.
–
SW exceeding
allowable memory
usage.
–
ID
77100
77100
77200
77200
77200
78000
78000
309