Cisco D9859 Installation And Configuration Manual page 224

Advanced receiver transcoder
Table of Contents

Advertisement

Chapter 5 Web GUI Setup and Monitoring
a
From the Use Input Channel Numbers drop-down list, choose Yes to use the
input channel numbers. Otherwise, set to No (default) to use the first channel
and channel offset assigned below.
i
ii In the Channel Numbers Offset field, set the subsequent PE channel
b From the Use Input PMT PID Numbers drop-down list, choose Yes to use
the input PMT PID number. Otherwise, choose No (default) to use the first
PE PID number and PID offset number assigned below.
i
ii In the PMT PID Numbers Offset field, set the offset of the subsequent PE
c
From the Use Input ES PID Numbers drop-down list, choose Yes to use the
input ES PID number. Otherwise, set to No (default) to use the first ES PID
number and the ES PID offset number assigned below.
i
ii In the First ES PID Numbers Offset field, set the offset of the subsequent
d From the Use Input PMT ES Stream Order drop-down list, choose Yes to
assign the ES PID according to the incoming PMT order. Otherwise, set to No
to use the reserved PIDs defined below.
i
e
Click OK.
4
From the Enable Auto Map For Auxiliary PEs drop-down list, choose Yes for
the DPM to set the output actions for all the auxiliary PEs to MAP when the
Output Mode is set to Transcode. If the Enable Fixed Table Output is set to Yes,
the output configuration for the auxiliary PEs is determined by the fixed output
table options when you resynchronize the output channels and PIDs to match
the input programs.
200
In the First Channel Number field, set the first PE channel number to
use. By default, the channel is set to 1.
numbers. For example, if the First Channel Number is set to 100 and the
Channel Numbers Offset is set to 10, then the first channel number is 100,
and the second channel number is 110.
In the First Channel First ES PID Number field, set the first PE PMT PID
number. The default is 1701.
PMT PID numbers. For example, if the First Channel First ES PID
Number is set to 1701 and the PMT PID Numbers Offset is set to 1, then
the first PMT PID number is 1701, and the second PMT PID number is
1702.
In the First Channel First ES PID Number field, set the first ES PID
number. The default is 101.
ES PID numbers. For example, if the First ES PID Number is set to 101
and the ES PID Numbers Offset is set to 100, then the first ES PID number
is 101, and the second ES PID number is 201.
In the PCR, VID, AUD, SUBT, VBI, DPI, MPE, TTX, DATA, LSD, CDT,
ETV fields, enter the number of PIDs for the specified streams (PCR, VID,
AUD, SUBT, VBI, DPI, MPE, TTX, DATA, LSD, CDT, ETV) in one
channel.