Advanced receiver transcoder
Table of Contents

Advertisement

Alarm
Message
Type
TXB ENC
Set
Temper. Alarm
TXB ENC
Clear
Temper. Alarm
ASI Out Status
Set
ASI Out Status
Clear
OL-31980 -01
Message
Cause/Remedy
Temperature
Cause: Room
over Alarm
temperature too
high, or air flow is
threshold
restricted.
Remedy: Check
the openings on
front and rear
panels for
blockage, assess
the room
temperature.
Lower the room
temperature or
improve air flow
to the device.
Temperature
normal
ASI Overflow.
Cause: Uplink
Output Muted.
settings may have
changed since
Reduce content.
setup of the unit.
Variable Bit
Rate/Statmuxed
streams may be in
use.
Remedy: Increase
the output rate,
drop unreferenced
content in DPM
Options, and/or
drop programs
not needed for
downstream
devices. Contact
your (uplink)
service provider to
verify the
expected bit rate
settings.
ASI Output
Restored
Description
Severity
The transcoder
Major
board encoder
temperature is
above safe
operating
range.
The transcoder
Major
board encoder
temperature is
within the safe
operating
range.
Current
Minor
transport rate
exceeds
configured rate
for ASI output.
Output has
been muted to
protect
downstream
devices.
Minor
ID
33100
33100
34000
34000
291