10
TOD1_0 Reload 0 Register (TOD10RL0)
TOD1_1 Reload 0 Register (TOD11RL0)
TOD1_2 Reload 0 Register (TOD12RL0)
TOD1_3 Reload 0 Register (TOD13RL0)
TOD1_4 Reload 0 Register (TOD14RL0)
TOD1_5 Reload 0 Register (TOD15RL0)
TOD1_6 Reload 0 Register (TOD16RL0)
TOD1_7 Reload 0 Register (TOD17RL0)
D0
1
2
D
Bit Name
0 - 15
TOD10RL0 - TOD17RL0
Note: This register must always be accessed in halfwords.
The TOD1 Reload 0 Register is used to reload the TOD1 Counter Registers (TOD10CT-TOD17CT)
with data. It is in the following cases that the content of reload 0 register is loaded into the counter:
• When the counter is enabled in single-shot output or PWM output mode
• When the counter underflowed in delayed single-shot output or continuous output mode
• When the count value set by reload 1 register underflowed in PWM output mode
Writing data to the reload 0 register does not mean that the data is loaded into the counter
simultaneously.
3
4
5
6
TOD10RL0 - TOD17RL0
Function
16-bit reload register value
10-185