MULTIJUNCTION TIMERS
10
10.4 TIO (Input/Output-related 16-bit Timer)
Measure event
Measure event
Enabled
(capture)
(capture)
(by writing to enable bit)
occurs
occurs
Count clock
Enable bit
H'FFFF
H'9000
Counter
H'7000
H'0000
H'7000
H'9000
Measure register
Indeterminate
TIN interrupt
TIN interrupt by
TIN interrupt by
external event input
external event input
TIO interrupt
TIO interrupt by
underflow
Note: This diagram does not show detail timing information.
Figure 10.4.8 Typical Operation in Measure Free-run Input Mode
10-126
Ver.0.10