Mitsubishi Electric M32R Series User Manual page 343

Mitsubishi 32-bit risc single-chip microcomputers
Table of Contents

Advertisement

10
TOP6,7 Control Register (TOP67CR)
D0
1
2
TOP7
TOP7M
ENS
D
Bit Name
0
No functions assigned
1
TOP7ENS
(TOP7 enable source selection)
2,3
TOP7M (TOP7 operation mode selection)
4,5
No functions assigned
6,7
TOP6M (TOP6 operation mode selection)
8
No functions assigned
9-11
TOP67ENS
(TOP6, TOP7 enable source selection)
12,13
No functions assigned
14,15
TOP67CKS
(TOP6, TOP7 clock source selection)
Note 1: This register must always be accessed in halfwords.
Note 2: Always make sure the counter has stopped and is idle before setting or changing operation modes.
3
4
5
6
TOP6M
10-73
MULTIJUNCTION TIMERS
10.3 TOP (Output-related 16-bit Timer)
7
8
9
10
11
TOP67ENS
Function
0: Result selected by TOP67ENS bit
1: TOP6 output
00: Single-shot output mode
01: Delayed single-shot output mode
1X: Continuous output mode
00: Single-shot output mode
01: Delayed single-shot output mode
1X: Continuous output mode
0XX: External TIN1 input
100: Input event bus 0
101: Input event bus 1
110: Input event bus 2
111: Input event bus 3
00: Clock bus 0
01: Clock bus 1
10: Clock bus 2
11: Clock bus 3
<Address:H'0080 02AA>
12
13
14
D15
TOP67CKS
<When reset:H'0000>
R
0
0
0
0
Ver.0.10
W

Advertisement

Table of Contents
loading

Table of Contents