Mitsubishi Electric M32R Series User Manual page 451

Mitsubishi 32-bit risc single-chip microcomputers
Table of Contents

Advertisement

10
TOD1 Control Registers (TOD1CR)
D0
1
2
TOD10M
TOD11M
D
Bit Name
0, 1
TOD10M
(TOD1_0 operation mode selection)
2, 3
TOD11M
(TOD1_1 operation mode selection)
4, 5
TOD12M
(TOD1_2 operation mode selection)
6, 7
TOD13M
(TOD1_3 operation mode selection)
8, 9
TOD14M
(TOD1_4 operation mode selection)
10, 11
TOD15M
(TOD1_5 operation mode selection)
12, 13
TOD16M
(TOD1_6 operation mode selection)
14, 15
TOD17M
(TOD1_7 operation mode selection)
The TOD1 Control Register is used to select TOD1_0-7 operation modes (PWM output, single-shot
output, delayed single-shot output, or continuous output mode).
3
4
5
6
TOD12M
TOD13M
10-181
MULTIJUNCTION TIMERS
10.8 TOD (Output-related 16-bit Timer)
7
8
9
10
11
TOD14M
TOD15M
Function
00 : Single-shot output mode
01 :Delayed single-shot output mode
10 : Continuous output mode
11 : PWM output mode
<Address: H'0080 0BDA>
12
13
14
D15
TOD16M
TOD17M
<When reset : H'0000>
R
Ver.0.10
W

Advertisement

Table of Contents
loading

Table of Contents