10.2.4 Input Processing Control Unit

The input processing control unit processes the TCLK and TIN signals fed into the MJT. In the
TCLK input processing unit, selection is made of the source of TCLK signal, or for external input,
the active edge (rising or falling or both) or level (high or low) of the signal, with or at which to
generate the clock signal fed to the clock bus.
In the TIN input processing unit, selection is made of the active edge (rising or falling or both) or
level (high or low) of the signal at which to generate the enable, measure or count source signal for
each timer or the signal fed to each event bus.
Following input processing control registers are included:
• TCLK Input Processing Control Register (TCLKCR)
• TIN Input Processing Control Register 0 (TINCR0)
• TIN Input Processing Control Register 1 (TINCR1)
• TIN Input Processing Control Register 2 (TINCR2)
• TIN Input Processing Control Register 3 (TINCR3)
• TIN Input Processing Control Register 4 (TINCR4)
10.2 Common Units of Multijunction Timer