13.3 Notices

13.3.1

Setting code

Each signal will be enabled by configuring the setting code "08-9016" (Counter installed externally).
08-9016
0: No external counter (Default)
1: Coin controller
2: Card controller (For Japan only)
3: Key copy counter
5: Coin controller supporting ACS/mixed-size
13.3.2
Setting value change and restrictions when using the Card
controller
1. Setting value
-
08-9016 (Counter installed externally): Set to "2" (Card controller).
-
08-9017 (Setting for counter installed externally): It should be charged precisely according to the
usage.
Example: To charge only when copies are made, set to "1".
2. Restrictions
-
08-6010 (Large size double count setting): Set to "0" (Single count).
13.3.3
Setting value change and restrictions when using the coin
controller
1. Setting value
-
08-9016 (Counter installed externally): Set to "1" (Coin controller).
-
08-9017 (Setting for counter installed externally): It should be charged precisely according to the
usage.
Example: To charge only when copies are made, set to "1".
2. Restrictions
For 08-6011 (Large size double count setting), set to "0" when A3 and LD are specified as the large
size, and set to "1" when B4, LG, FOLIO, COMP and 8K are specified as the large size in addition to
A3 and LD.
13.3.4

Setting value change and restrictions when using the key counter

1. Setting value
-
08-9016 (Counter installed externally): Set to "3" (key counter)
-
08-9017(Setting for counter installed externally): It should be charged precisely according to the
usage.
Example: To charge only when copies are made, set to "1".
2. Restrictions
-
08-6010 (Large size double count setting): Set to "0" (Single count).
-
For 08-6011 (Large size double count setting), set to "0" when A3 and LD are specified as the
large size, and set to "1" when B4, LG, FOLIO, COMP and 8K are specified as the large size in
addition to A3 and LD.
13.3.5
Installation of External Counter
It is not allowed to install more than one external counter (Key Counter, Card controller and Coin
controller) at the same time. Physically, the card controller and coin controller cannot be installed
together since the output signals are in common.