Provision Ethernet Ring Protection (ERP)
Figure 385
Two ERP Instances created
7. Select ERP Instance to provision Wait-to-Restore Time and Guard Timer.
8. Ring Node RPL Owner?
9. From the Wait-to Restore Time drop-down menu, select 1 to 12 minutes.
10. In the Guard Timer field, enter Guard Timer duration; 10 to 2000 ms.
11. Click Apply.
12. Repeat steps
572
a. If yes, repeat steps
See
Figure 384
for an example of two ERP Instances provisioned.
b. If no, go to step 7.
a. If yes, go to step 9.
b. If no, go to step 10.
7
and
11
second ERP Instance if applicable.
4
and
5
to create a second ERP Instance.
to provision Wait-to-Restore Time and Guard Timer on