Table F–2: IMPLEMENTATION TABLE (Sheet 4 of 4)
OBJECT
OBJECT
VARIATION
DESCRIPTION
NO.
NO.
34
2
32-bit Analog Input Reporting Deadband
cont'd
3
Short floating point Analog Input Reporting
Deadband
50
1
Time and Date
(default – see Note 1)
52
2
Time Delay Fine
60
0
Class 0, 1, 2, and 3 Data
1
Class 0 Data
2
Class 1 Data
3
Class 2 Data
4
Class 3 Data
70
0
File event - any variation
2
File authentication
3
File command
4
File command status
5
File transfer
6
File transfer status
7
File descriptor
80
1
Internal Indications
---
No Object (function code only)
see Note 3
---
No Object (function code only)
---
No Object (function code only)
Note 1:
A default variation refers to the variation responded when variation 0 is requested and/or in class 0, 1, 2, or 3 scans. The default varia-
tions for object types 1, 2, 20, 21, 22, 23, 30, and 32 are selected via relay settings. See the Communications section in Chapter 5 for
details. This optimizes the class 0 poll data size.
Note 2:
For static (non-change-event) objects, qualifiers 17 or 28 are only responded when a request is sent with qualifiers 17 or 28, respec-
tively. Otherwise, static object requests sent with qualifiers 00, 01, 06, 07, or 08, will be responded with qualifiers 00 or 01 (for change-
event objects, qualifiers 17 or 28 are always responded.)
Note 3:
Cold restarts are implemented the same as warm restarts – the N60 is not restarted, but the DNP process is restarted.
GE Multilin
N60 Network Stability and Synchrophasor Measurement System
F.1 DEVICE PROFILE DOCUMENT
REQUEST
FUNCTION
QUALIFIER
CODES (DEC)
CODES (HEX)
1
00, 01
(read)
(start-stop)
06
(no range, or all)
07, 08
(limited quantity)
17, 28
(index)
2
00, 01
(write)
(start-stop)
07, 08
(limited quantity)
17, 28
(index)
1
00, 01
(read)
(start-stop)
06
(no range, or all)
07, 08
(limited quantity)
17, 28
(index)
1
00, 01
(read)
(start-stop)
2
06
(write)
(no range, or all)
07
(limited qty=1)
08
(limited quantity)
17, 28
(index)
1
06
(read)
(no range, or all)
20
(enable unsol)
21
(disable unsol)
22
(assign class)
1
06
(read)
(no range, or all)
22
(assign class)
1
06
(read)
(no range, or all)
20
07, 08
(enable unsol)
(limited quantity)
21
(disable unsol)
22
(assign class)
1
06
(read)
(no range, or all)
07, 08
(limited quantity)
22
06
(assign class)
(no range, or all)
29
5b
(authenticate)
(free format)
25
5b
(open)
(free format)
27
(delete)
26
5b
(close)
(free format)
30
(abort)
1
5b
(read)
(free format)
2
(write)
28
5b
(get file info.)
(free format)
1
00, 01
(read)
(start-stop)
(index =7)
2
00
(write)
(start-stop)
(see Note 3)
(index =7)
13
(cold restart)
14
(warm restart)
23
(delay meas.)
RESPONSE
FUNCTION
QUALIFIER
CODES (DEC)
CODES (HEX)
129
00, 01
(response)
(start-stop)
17, 28
(index)
(see Note 2)
129
00, 01
(response)
(start-stop)
17, 28
(index)
(see Note 2)
129
00, 01
(response)
(start-stop)
17, 28
(index)
(see Note 2)
129
07
(response)
(limited quantity)
(quantity = 1)
129
5b
(response)
(free format)
129
5b
(response)
(free format)
130
(unsol. resp.)
129
5b
(response)
(free format)
130
(unsol. resp.)
129
5b
(response)
(free format)
130
(unsol. resp.)
129
5b
(response)
(free format)
130
(unsol. resp.)
129
00, 01
(response)
(start-stop)