GE N60 Instruction Manual page 520

Network stability and synchrophasor measurement system ur series
Hide thumbs Also See for N60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 66 of 70)
ADDR
REGISTER NAME
D909
...Repeated for DCmA Inputs 20
D91C
...Repeated for DCmA Inputs 21
D92F
...Repeated for DCmA Inputs 22
D942
...Repeated for DCmA Inputs 23
D955
...Repeated for DCmA Inputs 24
B
DNP/IEC Points (Read/Write Setting)
D968
DNP/IEC 60870-5-104 Binary Input Points (256 items)
DB68
DNP/IEC 60870-5-104 Analog Input Points (256 items)
Synchrocheck (Read/Write Setting) (4 Modules)
DC70
Synchrocheck 1 Function
DC71
Synchrocheck 1 V1 Source
DC72
Synchrocheck 1 V2 Source
DC73
Synchrocheck 1 Maximum Voltage Difference
DC75
Synchrocheck 1 Maximum Angle Difference
DC76
Synchrocheck 1 Maximum Frequency Difference
DC77
Synchrocheck 1 Dead Source Select
DC78
Synchrocheck 1 Dead V1 Maximum Voltage
DC79
Synchrocheck 1 Dead V2 Maximum Voltage
DC7A
Synchrocheck 1 Live V1 Minimum Voltage
DC7B
Synchrocheck 1 Live V2 Minimum Voltage
DC7C
Synchrocheck 1 Target
DC7D
Synchrocheck 1 Events
DC7E
Synchrocheck 1 Block
DC80
Synchrocheck 1 Frequency Hysteresis
DC81
...Repeated for Synchrocheck 2
DC92
...Repeated for Synchrocheck 3
DCA3
...Repeated for Synchrocheck 4
Phasor Measurement Unit Basic Configuration (Read/Write Setting) (1, 2, 4, or 6 Modules)
DCB4
PMU x Function
DCB5
PMU x LDInst
DCD6
PMU x IDcode
DCD7
PMU x STN
DCDF
PMU x Source
DCE0
PMU x Class
DCE1
PMU x Format
DCE2
PMU x Style
DCE3
PMU x Rate
DCE4
PMU x PHS-x (14 items)
DCF2
PMU x PHS-x Name (14 items)
DD62
PMU x A-CH-x (16 items)
DD72
PMU x A-CH-x (16 items)
DDF2
PMU x D-CH-x (16 items)
DE12
PMU x D-CH-x Name (16 items)
DE92
PMU x D-CH-x Normal State (16 items)
DEA2
PMU x Reserved (16 items)
DEB2
...Repeated for PMU 2
E0B0
...Repeated for PMU 3
E2AE
...Repeated for PMU 4
E4AC
...Repeated for PMU 5
E6AA
...Repeated for PMU 6
Phasor Measurement Unit Aggregator (Read/Write Setting) (1, 2, or 4 Modules)
E8A8
PMU Aggregator 1 Name
E8C9
Aggregator 1 IDcode
B-74
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
0 to 4294967295
---
0 to 65535
---
0 to 1
---
0 to 5
---
0 to 5
---
0 to 400000
V
0 to 100
degrees
0 to 2
Hz
0 to 5
---
0 to 1.25
pu
0 to 1.25
pu
0 to 1.25
pu
0 to 1.25
pu
0 to 2
---
0 to 1
---
0 to 4294967295
---
0 to 0.1
Hz
0 to 1
---
---
---
1 to 65534
---
---
---
0 to 5
---
0 to 2
---
0 to 1
---
0 to 1
---
0 to 13
---
0 to 14
---
---
---
0 to 65535
---
---
---
0 to 4294967295
---
---
---
0 to 1
---
0 to 1
---
---
---
1 to 65534
---
APPENDIX B
STEP
FORMAT
DEFAULT
1
F300
0
1
F600
0
1
F102
0 (Disabled)
1
F167
0 (SRC 1)
1
F167
1 (SRC 2)
1
F060
10000
1
F001
30
0.01
F001
100
1
F176
1 (LV1 and DV2)
0.01
F001
30
0.01
F001
30
0.01
F001
70
0.01
F001
70
1
F109
0 (Self-reset)
1
F102
0 (Disabled)
1
F300
0
0.01
F001
6
1
F102
0 (Disabled)
1
F214
"PMUx \040"
1
F001
1
---
F203
"GE-UR-PMU"
1
F167
0 (SRC 1)
1
F549
1 (Class M)
1
F547
0 (Integer)
1
F546
0 (Polar)
1
F544
4 (10/sec)
1
F543
1 (Va)
---
F203
"GE-UR-PMU-
PHS 1 "
1
F600
0
---
F203
"AnalogChannel 1
"
1
F300
0
---
F203
"Dig Channel 1 "
1
F108
0 (Off)
1
F001
0
1
F209
"MSVID 1 "
1
F001
1
GE Multilin

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents