B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 44 of 70)
ADDR
REGISTER NAME
Selector Switch Settings (Read/Write) (2 Modules)
A280
Selector 1 Function
A281
Selector 1 Range
A282
Selector 1 Timeout
A283
Selector 1 Step Up
B
A285
Selector 1 Step Mode
A286
Selector 1 Acknowledge
A288
Selector 1 Bit0
A28A
Selector 1 Bit1
A28C
Selector 1 Bit2
A28E
Selector 1 Bit Mode
A28F
Selector 1 Bit Acknowledge
A291
Selector 1 Power Up Mode
A292
Selector 1 Target
A293
Selector 1 Events
A294
Reserved (10 items)
A29E
...Repeated for Selector 2
Digital Counter (Read/Write Setting) (8 Modules)
A300
Digital Counter 1 Function
A301
Digital Counter 1 Name
A307
Digital Counter 1 Units
A30A
Digital Counter 1 Block
A30C
Digital Counter 1 Up
A30E
Digital Counter 1 Down
A311
Digital Counter 1 Preset
A313
Digital Counter 1 Compare
A315
Digital Counter 1 Reset
A317
Digital Counter 1 Freeze/Reset
A319
Digital Counter 1 Freeze/Count
A31B
Digital Counter 1 Set To Preset
A31D
Reserved (11 items)
A328
...Repeated for Digital Counter 2
A350
...Repeated for Digital Counter 3
A378
...Repeated for Digital Counter 4
A3A0
...Repeated for Digital Counter 5
A3C8
...Repeated for Digital Counter 6
A3F0
...Repeated for Digital Counter 7
A418
...Repeated for Digital Counter 8
Non Volatile Latches (Read/Write Setting) (16 Modules)
A700
Non-Volatile Latch 1 Function
A701
Non-Volatile Latch 1 Type
A702
Non-Volatile Latch 1 Set
A704
Non-Volatile Latch 1 Reset
A706
Non-Volatile Latch 1 Target
A707
Non-Volatile Latch 1 Events
A708
Reserved (4 items)
A70C
...Repeated for Non-Volatile Latch 2
A718
...Repeated for Non-Volatile Latch 3
A724
...Repeated for Non-Volatile Latch 4
A730
...Repeated for Non-Volatile Latch 5
A73C
...Repeated for Non-Volatile Latch 6
A748
...Repeated for Non-Volatile Latch 7
B-52
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
0 to 1
---
1 to 7
---
3 to 60
s
0 to 4294967295
---
0 to 1
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 1
---
0 to 4294967295
---
0 to 2
---
0 to 2
---
0 to 1
---
---
---
0 to 1
---
---
---
---
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
–2147483647 to
---
2147483647
–2147483647 to
---
2147483647
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
---
---
0 to 1
---
0 to 1
---
0 to 4294967295
---
0 to 4294967295
---
0 to 2
---
0 to 1
---
---
---
APPENDIX B
STEP
FORMAT
DEFAULT
1
F102
0 (Disabled)
1
F001
7
0.1
F001
50
1
F300
0
1
F083
0 (Time-out)
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F083
0 (Time-out)
1
F300
0
1
F084
0 (Restore)
1
F109
0 (Self-reset)
1
F102
0 (Disabled)
1
F001
0
1
F102
0 (Disabled)
---
F205
"Counter 1"
---
F206
(none)
1
F300
0
1
F300
0
1
F300
0
1
F004
0
1
F004
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
---
F001
0
1
F102
0 (Disabled)
1
F519
0 (Reset
Dominant)
1
F300
0
1
F300
0
1
F109
0 (Self-reset)
1
F102
0 (Disabled)
---
F001
0