B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 12 of 70)
ADDR
REGISTER NAME
2564
... Repeated for double-point status input 5
Phasor Measurement Unit Actual Values (Read Only) (6 Modules)
256D
PMU 1 Phase A Voltage Magnitude
256F
PMU Unit 1 Phase A Voltage Angle
2570
PMU 1 Phase B Voltage Magnitude
B
2572
PMU 1 Phase B Voltage Angle
2573
PMU 1 Phase C Voltage Magnitude
2575
PMU 1 Phase C Voltage Angle
2576
PMU 1 Auxiliary Voltage Magnitude
2578
PMU 1 Auxiliary Voltage Angle
2579
PMU 1 Positive Sequence Voltage Magnitude
257B
PMU 1 Positive Sequence Voltage Angle
257C
PMU 1 Negative Sequence Voltage Magnitude
257E
PMU 1 Negative Sequence Voltage Angle
257F
PMU 1 Zero Sequence Voltage Magnitude
2581
PMU 1 Zero Sequence Voltage Angle
2582
PMU 1 Phase A Current Magnitude
2584
PMU 1 Phase A Current Angle
2585
PMU 1 Phase B Current Magnitude
2587
PMU 1 Phase B Current Angle
2588
PMU 1 Phase C Current Magnitude
258A
PMU 1 Phase C Current Angle
258B
PMU 1 Ground Current Magnitude
258D
PMU 1 Ground Current Angle
258E
PMU 1 Positive Sequence Current Magnitude
2590
PMU 1 Positive Sequence Current Angle
2591
PMU 1 Negative Sequence Current Magnitude
2593
PMU 1 Negative Sequence Current Angle
2594
PMU 1 Zero Sequence Current Magnitude
2596
PMU 1 Zero Sequence Current Angle
2597
PMU 1 Frequency
2599
PMU 1 df/dt
259A
PMU 1 Configuration Change Counter
259B
Reserved (4 items)
259F
...Repeated for PMU 2
25D1
...Repeated for PMU 3
2603
...Repeated for PMU 4
2635
...Repeated for PMU 5
2667
...Repeated for PMU 6
Phasor Measurement Unit Integer Values (Read Only Actual Value Registers) (1, 2, 4, or 6 Modules)
2699
PMU 1 SOC Timestamp
269B
PMU 1 FRAMESEC Timestamp
269D
PMU 1 STAT Flags
269F
...Repeated for PMU 2
26A5
...Repeated for PMU 3
26AB
...Repeated for PMU 4
26B1
...Repeated for PMU 5
26B7
...Repeated for PMU 6
Phasor Measurement Unit Aggregator Actual Values (Read Only) (1, 2, or 4 Modules)
26BD
PMU 1 Aggregator PDU Size
26BE
...Repeated for PMU 2
26BF
...Repeated for PMU 3
26C0
...Repeated for PMU 4
B-20
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
0 to 999999.999
V
-180 to 180
°
0 to 999999.999
V
-180 to 180
°
0 to 999999.999
V
-180 to 180
°
0 to 999999.999
V
-180 to 180
°
0 to 999999.999
V
-180 to 180
°
0 to 999999.999
V
-180 to 180
°
0 to 999999.999
V
-180 to 180
°
0 to 999999.999
A
-180 to 180
°
0 to 999999.999
A
-180 to 180
°
0 to 999999.999
A
-180 to 180
°
0 to 999999.999
A
-180 to 180
°
0 to 999999.999
A
-180 to 180
°
0 to 999999.999
A
-180 to 180
°
0 to 999999.999
A
-180 to 180
°
2 to 90
Hz
-327.67 to 327.67
Hz/s
0 to 655.35
0 to 1
---
0 to 4294967295
seconds
0 to 4294967295
seconds
0 to 4294967295
---
---
---
APPENDIX B
STEP
FORMAT
DEFAULT
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F003
0
0.01
F002
0
0.01
F001
0
1
F001
0
1
F003
0
1
F003
0
1
F003
0
---
F001
0