GE N60 Instruction Manual page 522

Network stability and synchrophasor measurement system ur series
Hide thumbs Also See for N60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 68 of 70)
ADDR
REGISTER NAME
EA46
...Repeated for PMU 6
Phasor Measurement Unit Triggering (Read/Write Setting) (1, 2, 4, or 6 Modules)
EA4A
PMU 1 User Trigger
EA4C
...Repeated for PMU 2
EA4E
...Repeated for PMU 3
B
EA50
...Repeated for PMU 4
EA52
...Repeated for PMU 5
EA54
...Repeated for PMU 6
Phasor Measurement Unit Voltage Trigger (Read/Write Setting) (1, 2, 4, or 6 Modules)
EA56
PMU 1 Volt Trigger Function
EA57
PMU 1 Voltage Trigger Low Volt
EA58
PMU 1 Voltage Trigger High Volt
EA59
PMU 1 Voltage Trigger Pkp Time
EA5A
PMU 1 Voltage Trigger Dpo Time
EA5B
PMU 1 Voltage Trigger Block (3 items)
EA61
PMU 1 Voltage Trigger Target
EA62
PMU 1 Voltage Trigger Events
EA63
...Repeated for PMU 2
EA70
...Repeated for PMU 3
EA7D
...Repeated for PMU 4
EA8A
...Repeated for PMU 5
EA97
...Repeated for PMU 6
Phasor Measurement Unit Current Trigger (Read/Write Setting (1, 2, 4, or 6 Modules)
EAA4
PMU 1 Current Trigger Function
EAA5
PMU 1 Current Trigger Pickup
EAA6
PMU 1 Current Trigger Pkp Time
EAA7
PMU 1 Current Trigger Dpo Time
EAA8
PMU 1 Current Trigger Block (3 items)
EAAE
PMU 1 Current Trigger Target
EAAF
PMU 1 Current Trigger Events
EAB0
...Repeated for PMU 2
EABC
...Repeated for PMU 3
EAC8
...Repeated for PMU 4
EAD4
...Repeated for PMU 5
EAE0
...Repeated for PMU 6
Phasor Measurement Unit Frequency Trigger (Read/Write Setting) (1, 2, 4, or 6 Modules)
EAEC
PMU 1 Frequency Trigger Function
EAED
PMU 1 Frequency Trigger Low Frequency
EAEE
PMU 1 Frequency Trigger High Frequency
EAEF
PMU 1 Frequency Trigger Pickup Time
EAF0
PMU 1 Frequency Trigger Dropout Time
EAF1
PMU 1 Frequency Trigger Block (3 items)
EAF7
PMU 1 Frequency Trigger Target
EAF8
PMU 1 Frequency Trigger Events
EAF9
...Repeated for PMU 2
EB06
...Repeated for PMU 3
EB13
...Repeated for PMU 4
EB20
...Repeated for PMU 5
EB2D
...Repeated for PMU 6
Phasor Measurement Unit df/dt Trigger (Read/Write Setting) (1, 2, 4, or 6 Modules)
EB3A
PMU 1 df/dt Trigger Function
EB3B
PMU 1 df/dt Trigger Raise
EB3C
PMU 1 df/dt Trigger Fall
EB3D
PMU 1 df/dt Trigger Pkp Time
B-76
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
0 to 4294967295
---
0 to 1
---
0.25 to 1.25
pu
0.75 to 1.75
pu
0 to 600
s
0 to 600
s
0 to 4294967295
---
0 to 2
---
0 to 1
---
0 to 1
---
0.1 to 30
pu
0 to 600
s
0 to 600
s
0 to 4294967295
---
0 to 2
---
0 to 1
---
0 to 1
---
20 to 70
Hz
20 to 70
Hz
0 to 600
s
0 to 600
s
0 to 4294967295
---
0 to 2
---
0 to 1
---
0 to 1
---
0.1 to 15
Hz/s
0.1 to 15
Hz/s
0 to 600
s
APPENDIX B
STEP
FORMAT
DEFAULT
1
F300
0
1
F102
0 (Disabled)
0.001
F001
800
0.001
F001
1200
0.01
F001
10
0.01
F001
100
1
F300
0
1
F109
0 (Self-reset)
1
F102
0 (Disabled)
1
F102
0 (Disabled)
0.001
F001
1800
0.01
F001
10
0.01
F001
100
1
F300
0
1
F109
0 (Self-reset)
1
F102
0 (Disabled)
1
F102
0 (Disabled)
0.01
F001
4900
0.01
F001
6100
0.01
F001
10
0.01
F001
100
1
F300
0
1
F109
0 (Self-reset)
1
F102
0 (Disabled)
1
F102
0 (Disabled)
0.01
F001
25
0.01
F001
25
0.01
F001
10
GE Multilin

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents