2.2 ORDER CODES
The order codes for units with the process bus module are shown below.
Table 2–5: N60 ORDER CODES (WITH PROCESS BUS)
N60
-
*
**
- *
BASE UNIT
N60
|
|
CPU
T
|
2
U
|
V
|
SOFTWARE
00
03
06
07
14
15
16
17
A0
A3
A6
A7
AE
AF
AG
AH
B0
B3
B6
B7
BE
BF
BG
BH
C0
C3
C6
C7
CE
CF
CG
CH
D0
D3
D6
D7
DE
DF
DG
DH
E0
E3
E6
E7
EE
EF
EG
EH
F0
F3
F6
F7
FE
FF
FG
FH
G0
G3
G6
G7
GE
GF
GG
GH
I0
I1
I2
I3
I4
I5
I6
I7
I8
I9
IA
IB
IC
ID
IE
IF
IG
IH
II
IJ
IK
IL
J0
J3
J6
J7
JE
JF
JG
JH
K0
K3
K6
K7
KE
KF
KG
KH
L0
L3
L6
L7
LE
LF
LG
LH
MOUNT/COATING
2-10
*
* - F
**
- H
**
- M
**
- P
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
H
|
|
|
|
|
A
|
|
|
|
|
N60 Network Stability and Synchrophasor Measurement System

2.2.3 ORDER CODES WITH PROCESS BUS MODULES

**
- U
**
- W/X
**
Full Size Horizontal Mount
|
|
|
Base Unit
|
|
|
Three Multi-mode fiber 100Base-FX (SFP with LC)
|
|
|
Two Multi-mode fiber 100Base-FX (SFP with LC), One 10/100Base-T (SFP with RJ45)
|
|
|
Three 10/100Base-T (SFP with RJ45)
|
|
|
No software options
|
|
|
IEC 61850
|
|
|
Phasor measurement unit (PMU)
|
|
|
IEC 61850 and phasor measurement unit (PMU)
|
|
|
Two phasor measurement units (PMUs)
|
|
|
IEC 61850 and two phasor measurement units (PMUs)
|
|
|
Four phasor measurement units (PMUs)
|
|
|
IEC 61850 and four phasor measurement units (PMUs)
|
|
|
CyberSentry Lvl 1
|
|
|
CyberSentry Lvl 1 and IEC 61850
|
|
|
CyberSentry Lvl 1 and phasor measurement unit (PMU)
|
|
|
CyberSentry Lvl 1 and IEC 61850 and phasor measurement unit (PMU)
|
|
|
CyberSentry Lvl 1 and two phasor measurement units (PMUs)
|
|
|
CyberSentry Lvl 1 and IEC 61850 and two phasor measurement units (PMUs)
|
|
|
CyberSentry Lvl 1 and four phasor measurement units (PMUs)
|
|
|
CyberSentry Lvl 1 and IEC 61850 and four phasor measurement units (PMUs)
|
|
|
IEEE 1588
|
|
|
IEEE 1588 and IEC 61850
|
|
|
IEEE 1588 and phasor measurement unit (PMU)
|
|
|
IEEE 1588 and IEC 61850 and phasor measurement unit (PMU)
|
|
|
IEEE 1588 and two phasor measurement units (PMUs)
|
|
|
IEEE 1588 and IEC 61850 and two phasor measurement units (PMUs)
|
|
|
IEEE 1588 and four phasor measurement units (PMUs)
|
|
|
IEEE 1588 and IEC 61850 and four phasor measurement units (PMUs)
|
|
|
Parallel Redundancy Protocol (PRP)
|
|
|
PRP and Ethernet Global Data
|
|
|
PRP and PMU
|
|
|
PRP, IEC 61850, and PMU
|
|
|
PRP and two PMUs
|
|
|
PRP, IEC 61850, and two PMUs
|
|
|
PRP and four PMUs
|
|
|
PRP, IEC 61850, and four PMUs
|
|
|
IEEE 1588 and CyberSentry Lvl 1
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and phasor measurement unit (PMU)
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and phasor measurement unit (PMU)
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and two phasor measurement units (PMUs)
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and two phasor measurement units (PMUs)
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and four phasor measurement units (PMUs)
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and four phasor measurement units (PMUs)
|
|
|
IEEE 1588 and PRP
|
|
|
IEEE 1588, PRP, and IEC 61850
|
|
|
IEEE 1588, PRP, and PMU
|
|
|
IEEE 1588, PRP, IEC 61850, and PMU
|
|
|
IEEE 1588, PRP, and two PMUs
|
|
|
IEEE 1588, PRP, IEC 61850, and two PMUs
|
|
|
IEEE 1588, PRP, and four PMUs
|
|
|
IEEE 1588, PRP, IEC 61850, and four PMUs
|
|
|
PRP and CyberSentry Lvl1
|
|
|
PRP, CyberSentry Lvl 1, and IEC 61850
|
|
|
PRP, CyberSentry Lvl 1, and PMU
|
|
|
PRP, CyberSentry Lvl 1, IEC 61850, and PMU
|
|
|
PRP, CyberSentry Lvl 1, and two PMUs
|
|
|
PRP, CyberSentry Lvl 1, IEC 61850, and two PMUs
|
|
|
PRP, CyberSentry Lvl 1, and four PMUs
|
|
|
PRP, CyberSentry Lvl 1, IEC 61850, and four PMUs
|
|
|
IEEE 1588, PRP, and CyberSentry Lvl 1
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, and PMU
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and PMU
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, two PMUs
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and two PMUs
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, four PMUs
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and four PMUs
|
|
|
Six PMUs
|
|
|
Six PMUs + IEC 61850
|
|
|
Six PMUs + CyberSentry Lvl 1
|
|
|
Six PMUs + IEC 61850 + CyberSentry Lvl 1
|
|
|
Six PMUs + IEEE 1588
|
|
|
Six PMUs + IEEE 1588 + IEC 61850
|
|
|
Six PMUs + PRP
|
|
|
Six PMUs + PRP + IEC 61850
|
|
|
Six PMUs + IEEE 1588 + CyberSentry Lvl 1
|
|
|
Six PMUs + IEEE 1588 + CyberSentry Lvl 1 + IEC 61850
|
|
|
Six PMUs + PRP + IEEE 1588
|
|
|
Six PMUs + PRP + IEEE 1588 + IEC 61850
|
|
|
Six PMUs + PRP + CyberSentry Lvl 1
|
|
|
Six PMUs + PRP + CyberSentry Lvl 1 + IEC 61850
|
|
|
Six PMUs + PRP + CyberSentry Lvl 1 + IEEE 1588
|
|
|
Six PMUs + PRP + CyberSentry Lvl 1 + IEEE 1588 + IEC 61850
|
|
|
Six PMUs + IEC 60870-5-103
|
|
|
Six PMUs + IEC 60870-5-103 + IEC 61850
|
|
|
Six PMUs + IEC 60870-5-103 + PRP + IEEE 1588
|
|
|
Six PMUs + IEC 60870-5-103 + PRP + IEEE 1588 + IEC 61850
|
|
|
Six PMUs + IEC 60870-5-103 + PRP + IEEE 1588 + CyberSentry Lvl 1
|
|
|
Six PMUs + IEC 60870-5-103 + PRP + IEEE 1588 + CyberSentry Lvl 1 + IEC 61850
|
|
|
IEC 60870-5-103
|
|
|
IEC 60870-5-103 + IEC 61850
|
|
|
IEC 60870-5-103 + PMU
|
|
|
IEC 60870-5-103 + IEC 61850 + PMU
|
|
|
IEC 60870-5-103 + two PMUs
|
|
|
IEC 60870-5-103 + IEC 61850 + two PMUs
|
|
|
IEC 60870-5-103 + four PMUs
|
|
|
IEC 60870-5-103 + IEC 61850 + four PMUs
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103 + IEC 61850
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103 + PMU
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103 + IEC 61850 + PMU
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103 + two PMUs
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103 + IEC 61850 + two PMUs
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103 + four PMUs
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103 + IEC 61850 + four PMUs
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + IEC 61850
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + PMU
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + IEC 61850 + PMU
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + two PMUs
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + IEC 61850 + two PMUs
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + four PMUs
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + IEC 61850 + four PMUs
|
|
|
Horizontal (19" rack)
|
|
|
Horizontal (19" rack) with harsh environmental coating