Programming
Function Keys: This feature allows the user to rapidly enable/disable various fire panel inputs and outputs during scheduled
maintenance.
Banner: This option allows the user to change the top two lines of the LCD display from the blank factory default readout to a user
defined readout when the control panel is in Normal condition.
Time/Date: This feature allows the programmer to set the time, display format (24 hr or 12 hr), date and daylight savings time feature
into the FACP memory
Timers: This option allows the programmer to set the PAS (Positive Alarm Sequence) time delay, Pre-Signal time delay and Waterflow
time delay.
NACs: This feature allows the programmer to configure the control panel Notification Appliance Circuits for a variety of options, such
as circuit type, silenceable/nonsilenceable, autosilence, coding, silence inhibit, zone assignment and enable/disable.
Relays: This option allows programming of two onboard relays for activation by various control panel events, such as alarm, trouble,
supervisory, etc.
Canadian Option: This option allows the programming of certain options to Canadian specifications.
Waterflow Silenceable: This option provides the ability to silence any output circuit activated by a monitor module programmed as a
waterflow type.
Auxiliary Power: This option configures the use of the 24VDC auxiliary power output at TB11 on the FACP.
Trouble Reminder: This feature provides an audible reminder that an alarm or trouble still exists on the FACP after the control panel has
been silenced. The control panel piezo sounder will pulse once every 15 seconds during an alarm and every two minutes during a
trouble condition, after the Alarm Silence or Acknowledge key is pressed. The piezo will continue to sound at these rates until the alarm
or trouble condition is cleared. If the trouble condition is not cleared within a selected time of either 4 or 24 hours, the panel will
reactivate the local trouble sounder at the panel. When used with SWIFT wireless devices, the Trouble Reminder must be set to 4 hours.
Language: This option allows the user to switch between English and French language text on the panel display.
4XTM Supervision: This feature enables supervision of an installed 4XTMF Transmitter Module.
Remote Sync Enable: This feature controls the activation of notification appliances in such a way that all devices will turn on and off at
exactly the same time.
Charger Enable: This option allows the user to install an external battery charger.
Battery Size: This option allows the user to select the size of the battery being used to allow for proper charging of the panel.
PROGRAMMING
1=LOOP SETUP
2=SYSTEM SETUP
3=NOT USED
Programming Screen #2

Function Keys

The ES-1000X keypad has 4 programmable function keys. These keys can be programmed to allow rapid disable/enable of various fire panel
inputs and outputs during scheduled maintenance. Pressing any function key results in a trouble signal at the panel. Pressing 1 on System
Setup Screen #1 displays the following:
Select 1, 2, 3, or 4 to program the corresponding Function Key. The following screens display for each Function Key where "(X)" represents
the number of the key chosen.
To Enable or Disable the Function Key, press the 1 key while viewing the Function Keys Screen #1. Each press of the key will toggle the
screen between Key Enabled Yes and Key Enabled No.
Pressing 2 key while viewing the Function Keys Screen #1 allows the user to select individual zones that the Function Key will disable.
Pressing 3 assigns all zones to the selected Function Key. This button toggles All Zones Included On and All Zones Included Off. Note that no
change appears on the screen when this button is pressed. However, the user can verify the change by pressing 2 to see the Zones listed.
68
Pressing 2 for System Setup, while viewing Programming Screen #2, will cause the following screens to be dis-
played:
SYSTEM SETUP
1=FUNCTION KEYS
2=BANNER
3=TIME/DATE
System Setup Screen #1
SYSTEM SETUP
1=AUX POWER
2=TROUBLE REM
24HR
3=LANGUAGE
System Setup Screen #4
1=F1
2=F2
Function Keys Screen
F(X) KEY OPERATION
1=KEY ENABLED
YES
2=ZONES
3=ALL ZONES
Function Keys Screen #1
SYSTEM SETUP
1=TIMERS
2=NAC
3=RELAYS
System Setup Screen #2
SYSTEM SETUP
1=4XTM SPV ENAB
2=REM SYNC ENAB
3=NOT USED
System Setup Screen #5
FUNCTION KEYS
3=F3
4=F4
F(X) KEY OPERATION
1=NACS
2=REM SYNC DISB
Function Keys Screen #2
ES-1000X Series Manual — P/N LS10133-000FL-E:A 6/21/2023
Master Programming Level
SYSTEM SETUP
1=CANADIAN OPT. OFF
2=WATERFLOW SIL. NO
3=MNS OVERRIDE
System Setup Screen #3
SYSTEM SETUP
1=CHARGER ENAB
NO
YES
2=BAT SIZE 18-26 AH
3=NOT USED
System Setup Screen #6
1,2,3,4
NO
NO
YES