Programming
ANN-I/O Options
Pressing 2 for Module Options while viewing ANN-BUS Address screen when the ANN-I/O option is selected will display the following
screen:
ANN-I/O - ADDR X-1
SLC 1 DET 001-030
ACTIVE LEDS ONLY
ANN-I/O Address Screen #1
The first screen indicates that the ANN-I/O at ANN-BUS address 1 is programmed to annunciate SLC Loop #1 addressable Detectors with
addresses 1 through 30. The programming can be changed using ANN-I/O Address Screens 2 and 3.
Pressing 1 while viewing ANN-I/O Address Screen #2 will program the annunciator module to annunciate either Point (addressable device
address) information or Zone information.
Pressing 1 while viewing ANN-I/O Address Screen #3 will select the Point or Zone range to be annunciated (refer to the tables in "ANN-I/O
Zone Option" on page 88 and "ANN-I/O Point Option" on page 89).
Pressing 2 while viewing ANN-I/O Address Screen #3 will select either addressable detectors or addressable modules to be annunciated.
Pressing 3 while viewing ANN-I/O Address Screen #3 will select the SLC Loop with the addressable devices to be annunciated.
ANN-I/O Zone Option
If Zone is selected as the module option, the first ten LEDs on the first ANN-I/O module will display the system status information. The
remaining 30 LEDs on the first module and 40 LEDs on the remaining modules will display the active/alarm status of each zone in the Zone
Range programmed for that particular module. The LED assignments for each ANN-I/O module will be as follows.
Module
LED
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
88
ANN-I/O
ANN-I/O
Module #1
Module #2
Function
Function
AC Fault
Zone 30
Fire Alarm
Zone 31
Supervisory
Zone 032
Trouble
Zone 033
Alarm Silenced
Zone 034
Earth Fault
Zone 035
Battery Fault
Zone 036
Charger Fault
Zone 037
NAC Fault
Zone 038
Disabled
Zone 039
Zone 000
Zone 040
Zone 001
Zone 041
Zone 002
Zone 042
Zone 003
Zone 043
Zone 004
Zone 044
Zone 005
Zone 045
Zone 006
Zone 046
Zone 007
Zone 047
Zone 008
Zone 048
Zone 009
Zone 049
Zone 010
Zone 050
Zone 011
Zone 051
Zone 012
Zone 052
Zone 013
Zone 053
Zone 014
Zone 054
Zone 015
Zone 055
Zone 016
Zone 056
Zone 017
Zone 057
Zone 018
Zone 058
Zone 019
Zone 059
Zone 020
Zone 060
ANN-I/O - ADDR X-1
1=POINT/ZONE
POINT
ANN-I/O Address Screen #2
ANN-I/O
ANN-I/O
Module #3
Module #4
Function
Function
Zone 70
Zone 110
Zone 71
Zone 111
Zone 072
Zone 112
Zone 073
Zone 113
Zone 074
Zone 114
Zone 075
Zone 115
Zone 076
Zone 116
Zone 077
Zone 117
Zone 078
Zone 118
Zone 079
Zone 119
Zone 080
Zone 120
Zone 081
Zone 121
Zone 082
Zone 122
Zone 083
Zone 123
Zone 084
Zone 124
Zone 085
Zone 125
Zone 086
Zone 126
Zone 087
Zone 127
Zone 088
Zone 128
Zone 089
Zone 129
Zone 090
Zone 130
Zone 091
Zone 131
Zone 092
Zone 132
Zone 093
Zone 133
Zone 094
Zone 134
Zone 095
Zone 135
Zone 096
Zone 136
Zone 097
Zone 137
Zone 098
Zone 138
Zone 099
Zone 139
Zone 100
Zone 140
ES-1000X Series Manual — P/N LS10133-000FL-E:A 6/21/2023
Master Programming Level
ANN-I/O - ADDR X-1
1=RANGE
PT001-030
2=DET/MOD
DET
3=SLC LOOP #
ANN-I/O Address Screen #3
ANN-I/O
ANN-I/O
Module #5
Module #6
Function
Function
Zone 150
Zone 190
Zone 151
Zone 191
Zone 152
Zone 192
Zone 153
Zone 193
Zone 154
Zone 194
Zone 155
Zone 195
Zone 156
Zone 196
Zone 157
Zone 197
Zone 158
Zone 198
Zone 159
Zone 199
Zone 160
Zone 200
Zone 161
Zone 201
Zone 162
Zone 202
Zone 163
Zone 203
Zone 164
Zone 204
Zone 165
Zone 204
Zone 166
Zone 205
Zone 167
Zone 206
Zone 168
Zone 207
Zone 169
Zone 208
Zone 170
Zone 210
Zone 171
Zone 211
Zone 172
Zone 212
Zone 173
Zone 213
Zone 174
Zone 214
Zone 175
Zone 215
Zone 176
Zone 216
Zone 177
Zone 217
Zone 178
Zone 218
Zone 179
Zone 219
Zone 180
Zone 220
1
ANN-I/O
Module #7
Function
Zone 230
Zone 231
Zone 232
Zone 233
Zone 234
Zone 235
Zone 236
Zone 237
Zone 238
Zone 239
Zone 240
Zone 241
Zone 242
Zone 243
Zone 244
Zone 245
Zone 246
Zone 247
Zone 248
Zone 249
Zone 250
Zone 251
Zone 252
Zone 253
Zone 254
Zone 255
Not Used
Not Used
Not Used
Not Used
Not Used

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fire-lite alarms es-1000xcFire-lite alarms es-1000xi

Table of Contents