Sign In
Upload
Manuals
Brands
Honeywell Manuals
Control Panel
NOTIFIER NCA-2
Honeywell NOTIFIER NCA-2 Manuals
Manuals and User Guides for Honeywell NOTIFIER NCA-2. We have
4
Honeywell NOTIFIER NCA-2 manuals available for free PDF download: Instruction Manual, Wiring Manual, Programming And Operations Manual, Product Installation Document
Honeywell NOTIFIER NCA-2 Instruction Manual (108 pages)
Network Control Annunciator
Brand:
Honeywell
| Category:
Control Panel
| Size: 3.22 MB
Table of Contents
Table of Contents
5
Section 1: about this Manual
8
Standards and Specifications
8
UL 864 Compliance
8
1: UL 864 9Th and 10Th Edition
8
Programming Features Subject to AHJ Approval
8
Related Documentation
10
Notes, Cautions, and Warnings
11
Conventions
11
Section 2: Overview
12
General Description
12
1: NCA-2 Features
12
2: Compatibility with NOTI•FIRE•NET™ Panel Nodes
13
NCA-2 and Displayless Panels
14
NCA-2 / NFS2-640 Standalone Application
14
NCA-2 Board Layout
16
NCA-2 Keypad Layout
17
NCA-2 Components
17
1: NCA-2 Basic Components
17
2: EIA-232 Optional Devices
17
3: EIA-485 Annunciator Devices
17
4: Other Optional Devices
18
Section 3: Installation
19
Preparing for Installation
19
Installation Checklist
19
CAB-4 Series Cabinet
20
ABS-2D, ABS-4D Cabinets
21
CHS-M3 Chassis
22
1: Layout
22
2: NCA-2 Mounting
22
3: Memory-Backup Battery
23
4: Option Boards
24
CA-2 Chassis Assembly
24
NCA-2 / NFS2-640 Standalone
26
Retrofits
26
Form-C Relays on the NCA-2
26
Network Communications Module
27
Central Station Fire Alarm System Canadian Requirements
28
Connecting Power Sources and Outputs
29
1: Overview
29
2: Connecting the Power Supply
29
3: Checking AC Power
30
4: Power Considerations When Servicing
30
UL Power-Limited Wiring Requirements
30
Installing Printers
31
1: Printer Installation Sequence
31
2: Configuring the Printer
32
Connecting a PC for Programming
33
Annunciator Key Switch (AKS-1B)
33
Security Tamper Switch
34
ACS Devices and the NCA-2
34
LCD-160, LCD-80, LCD2-80 and NCA-2
35
Section 4: Operation
36
The Keypad
36
1: Fixed Function Keys
36
2: Special Function Keys
37
3: Soft Keys
37
4: Diagnostic Indicators and Controls
37
The LCD Display
37
1: Basic Screen Navigation: the Main Menu
38
2: Event Counts Display
39
3: Multiple Event List
40
4: Local and Node History Display
41
5: Read Status
45
6: Program/Alter Status
48
7: Printer Functions
48
Events
52
1: about Events
52
2: Types of Events
52
3: Event Handling
52
Section 5: Programming
54
Security Access
54
1: Master Password
54
2: User Password
54
3: Unprotected Functions
55
4: Key Switches
55
The Program/Alter Status Menu
56
Alter Status Menu
57
1: Alter Status Menu Options
57
2: Disable/Enable
57
3: Changing Detector Sensitivity
58
4: Clear Verify Counters
59
5: Clear History
60
6: Walk Test
60
7: Change Time/Date
62
8: Control On/Off
62
Node Program Menu
64
1: Node Program Menu Options
64
2: Edit Point Labels
64
3: Edit Node Label (for a Remote Node)
65
Panel Program Menu
65
1: Network Parameters
66
2: Network Mapping
67
3: Panel Settings
68
4: Panel Timers
71
5: LCD Display
72
6: ACS Programming
73
7: Supervision
78
8: more Menu
80
Point Program Menu
80
1: DVC/Daa
81
2: Logic Zone
82
3: Annunciator Board Label
85
4: General Zone
86
Delete Programming
87
E.1: Singapore
92
E.2: Chicago
92
E.3: Australia
93
E.4: China
93
E.5: Canada
93
F.1: Conversions Common to UL 8Th Edition Panels
95
F.2: Am2020/Afp-1010
95
F.3: Afp-300/Afp-400
96
F.4: Afp-200
97
G.1: Equations
99
G.1.1: Arguments
99
G.1.2: Logic Equations
99
Index
102
Section 1 Operating Information
105
Section 1: Normal Standby Operation
105
Alarm Condition
105
Advertisement
Honeywell NOTIFIER NCA-2 Wiring Manual (80 pages)
Intelligent Control Panel SLC
Brand:
Honeywell
| Category:
Control Panel
| Size: 2.84 MB
Table of Contents
Table of Contents
5
Section 1: Introduction
8
About this Manual
8
UL 864 Compliance
8
1: Products Subject to AHJ Approval
8
Reference Documentation
9
SLC Overview
11
Polling Protocols
11
1: Available Protocols
11
2: Protocol Use
12
Devices
12
1: Monitor/Zone Interface Module
12
2: Control Modules
12
3: Isolator Modules
12
4: Relay Modules
13
5: Multiple Input/Output Modules
13
6: Transponders
13
7: Plug-In Detector Bases
13
8: Intelligent Detectors
13
9: Addressable Manual Pull Stations
14
10: Wireless Interface
14
11: ACPS-610 Addressable Charger/Power Supply
14
12: ACPS-2406 Addressable Charger/Power Supply
14
13: AMPS-24 Addressable Power Supply
14
SLC Capacity
15
SLC Performance
15
LED Operation
15
Section 2: Wiring Requirements
16
Recommended SLC Wiring
16
Two-Wire SLC - Style 4 (Class B)
17
1: Measuring Loop Resistance
17
2: Measuring Total Wire Length
18
Four-Wire SLC Style 6 & 7 (Class A)
18
1: Measuring Loop Resistance
18
2: Measuring Total Wire Length
19
Control Panel Terminal Blocks
19
1: NFS2-3030 and NFS-3030 with LCM-320, LEM-320
19
2: NFS2-640 with Loop Expander Modules, NFS-320 and NFS-320SYS
20
3: NFS-640 with Loop Expander Modules
20
4: Afp-100
20
5: Afp-200
20
6: Afp-300/Afp-400
21
7: AM2020/AFP1010 with LIB-200A or LIB-400
21
8: System 5000 with AIM-200
21
Section 3: Shielded Wire Termination
22
Overview
22
No Conduit
22
Full Conduit
22
Partial Conduit
23
Floating Shield
23
Section 4: SLC Circuits Without Isolators
24
Overview
24
NFPA Style 4 SLC
24
NFPA Style 6 SLC
25
Section 5: SLC Circuits with Isolators
26
Overview
26
Fault Isolator Modules
26
Isolator Detector Bases
27
1: How an Isolator Base Works
27
NFPA Style 4 SLC Using Isolator Modules
29
NFPA Style 6 SLC Using Isolator Modules
31
NFPA Style 7 SLC Using an Isolating Device
32
Section 6: Monitor Modules
33
Description
33
1: Addressable Monitor Module
33
2: Zone Interface Module
33
3: Miniature Monitor Module
34
4: FMM-4-20 4-20Ma Monitor Module
34
Setting an SLC Address for a Module
35
NFPA Style B IDC Using Monitor Modules
35
NFPA Style D IDC Using Monitor Modules
36
NFPA Style B IDC Using Zone Interface Modules
37
NFPA Style D IDC Using Zone Interface Modules
38
Section 7: Control Modules
40
Description
40
1: Setting an SLC Address
40
Wiring a NAC with Addressable Control Modules
40
1: Wiring a Solenoid with the FCM-1-REL
41
Wiring a Style y NAC (Two-Wire) with Addressable Control Modules
41
Wiring a Style Z NAC (Four-Wire) with Addressable Control Modules
42
Connecting a Releasing Device to the Addressable Control Module
43
Section 8: Relay Module
44
Description
44
1: Setting an SLC Address
44
Wiring the Addressable Relay Module (Form-C Relay)
44
Section 9: Multiple Input/Output Modules
45
Description
45
1: Fdm-1
45
2: Fdrm-1
45
Setting the SLC Address
45
Wiring the Dual Monitor Module
45
Wiring the Addressable Dual Monitor/Dual Relay Module
46
NFPA Style B IDC Wiring Using Dual Monitor Modules
46
Section 10: Intelligent Detectors, Intelligent Detector Bases, and Wireless Gateway
48
Description
48
1: Intelligent Detector Bases
48
2: Intelligent Aspiration Detectors
48
3: Wireless Gateway
48
Wiring a Detector Base
49
Wiring an Isolator Base
51
Wiring a Relay Base
51
Wiring a Sounder Base
52
Wiring and Programming Aspiration Detectors
52
Wiring the FWSG
54
1: SLC Connections
54
Power Connections: Powered by the SLC
55
1: Power Connections: External, Regulated +24 VDC Power Source
56
Section 11: Addressable Manual Pull Station
57
Description
57
1: Setting an SLC Address
57
Wiring a Manual Pull Station
57
Appendix A: Power Considerations
58
A.1: Supplying Power to 24 VDC Detectors and Nacs
58
A.2: Supervising 24 VDC Power
58
A.2.1: Using Type Codes with Built-In Power Supervision on the NFS2-3030, NFS-3030, NFS2-640, NFS-320 and NFS-320SYS
58
A.2.2: Power Supervision Relay
58
A.2.3: Using the Addressable Control Module Without Relay
60
Appendix B: SLC Surge Suppression
62
B.1: Introduction
62
B.2: Installation
62
B.2.1: Afp-100 & Afp-200
63
B.2.2: Afp-300, Afp-400
63
B.2.3: AM2020 & AFP1010(LIB-200A or LIB-400)
64
B.2.4: NFS2-3030, NFS-3030, NFS2-640, NFS-640, NFS-320, and NFS-320SYS
65
Appendix C: Terminal Conversion Charts for V-Type and H-Type Devices
67
C.1: Frm-1
67
C.2: FCM-1 and FZM-1
68
C.3: Fmm-1
68
C.4: Ftm-1
68
C.5: Fdm-1
69
Appendix D: Intelligent Detector Base Layouts for Legacy Devices
70
D.1: Wiring a Detector Base
70
D.2: Wiring an Isolator Base
71
D.3: Wiring a Relay Base
71
D.4: Wiring a Sounder Base
72
Appendix E: Canadian Versions of SLC Devices
73
Index
76
Honeywell NOTIFIER NCA-2 Programming And Operations Manual (46 pages)
Mass Notification System
Brand:
Honeywell
| Category:
Security System
| Size: 1 MB
Table of Contents
Table of Contents
5
Section 1: Introduction
6
Overview
6
Mass Notification Features
7
Supplemental Documentation
8
Cautions and Warnings
8
Section 2: Configurations
9
Autonomous Control Unit (ACU)
9
1: Description
9
2: Configurations
9
Local Operating Console (LOC)
10
1: Description
10
2: Configurations
10
Central Control Station (CCS)
11
1: Description
11
2: Configurations
11
MN Alarm Indicator
13
Inputs
13
1: Monitor Module and Initiating Device
13
2: Microphone Activations for MN
14
3: ACS and DVC-KD Activations
14
Outputs
14
1: Strobes and Horns
14
2: Speakers
14
3: CAP Gateway
14
Supplemental Equipment
14
Section 3: Programming
15
Overview
15
Programming Steps
15
1: Acu
15
2: Loc
16
3: Ccs
16
4: Subsidiary Equipment
17
Programming
18
1: DCC Participation
18
2: Mass Notification Control Settings for the DVC
19
3: Set the Priority
19
4: MN Mapping
23
5: Type Ids
24
6: Special Function Zones
25
7: MN Active Tone
25
8: Fire Active Tone
29
9: DVC-Rpu
33
10: Lcd-160
33
11: MN Annunciator Programming
34
12: DVC General Zones
34
13: MN Control Label
35
Section 4: Operation
36
Mass Notification Events
36
1: MN Alarm
36
2: MN Supervisory
37
3: MN Trouble
38
Performing a System Reset
39
Output Event Suppression
40
Mass Notification Control Operation
41
Paging
42
Drill Operation
42
Index
43
Advertisement
Honeywell NOTIFIER NCA-2 Product Installation Document (18 pages)
High-Speed Network Communications Module
Brand:
Honeywell
| Category:
Network Hardware
| Size: 0.89 MB
Table of Contents
Installation
9
Mounting Options
9
Diagnostic Indicators
16
Supplemental Documentation
18
Advertisement
Related Products
Honeywell nfs2-3030
Honeywell Notifier NFS-320
Honeywell Notifier NFS-320SYS
Honeywell NOTIFIER NFW-50X
Honeywell NOTIFIER NFS-640
Honeywell NOTIFIER NFW-100X
Honeywell NOTIFIER SLC
Honeywell Notifier NFS-320/E/C
Honeywell NOTIFIER N16
Honeywell Notifier ID50
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL