NFPA Standard-Specific Requirements
C.1 MBT-1 Municipal Box Trip - Silenceable
The following figure illustrates the connection of the MBT-1 (Municipal Box Trip) between the FACP and a Local Energy Municipal Box.
The use of an addressable control module programmed for General Alarm and Silenceable allows silencing of the Municipal Box without
resetting the panel or box.
The addressable Control Module must be programmed
as Silenceable and General Alarm.
-
*If the SLC device does not match the one in this figure, refer to the SLC manual wiring conversion charts for legacy and newer
versions of the modules.
140
CMF-300
Control Module*
Alarm polarity shown!
+
Figure C.4 MBT-1 Silenceable
Connect wires to two
red terminals on box.
Note: 10Ω maximum loop
resistance due to wiring from
power supply to Municipal Box.
(All contacts shown in energized position).
- To next device
+ on SLC Loop
EOLR-1 Power
Supervision Relay
SLC Loop
24 VDC, Non-resettable
+
-
B
B
SLC-3LS card
ES-1000X Series Manual — P/N LS10133-000FL-E:A 6/21/2023
MBT-1 Municipal Box Trip - Silenceable
Gamewell Model M34-56
Local Energy Municipal Box
MBT-1
white wire
brown wire
red
+
-